Thread
:
bath fan venting question
View Single Post
#
2
Posted to alt.home.repair
willshak
external usenet poster
Posts: 3,482
bath fan venting question
on 11/12/2007 8:34 PM
said the following:
I am putting in a bathroom in my basement and know I need to vent the
fan. I plan on running the vent between the joists, but I'll need to
jog around the i-beam. is it okay to use flexible dryer-vent type
pipe to come down and then back up to get around the structural beam?
Essentially it would look lik ~~~~U~~~~~~ where the U is the flexible
vent pipe going underneath the beam? Other suggestions?
Thanks,
That U might pose a problem if you vent it out the attic roof. Think
P-trap. Even shower mist could condensate on the inner walls of the pipe
and fill the U.
--
Bill
In Hamptonburgh, NY
To email, remove the double zeroes after @
Reply With Quote
willshak
View Public Profile
Find all posts by willshak