View Single Post
  #5   Report Post  
Posted to alt.home.repair
DonC DonC is offline
external usenet poster
 
Posts: 82
Default new water filter/softener system help


"benick" wrote in message
. ..

"DonC" wrote in message
...

"benick" wrote in message
...
Recently had my submersiable water pump , expanson tank replaced and new
water filter/softener system installed(hard rusty water) and after a
month or so I seem to still have air in the system. The water is milky
but clears quickly and I can hear air in the pipes. What could be the
likely cause? Gonna call the company that did the install but wanted to
make sure it wasn't something stupid I could easily fix myself first.
Thanks for any help.......

Did you by any chance get an iron filter as part of the installation? If
so, that would explain the air in the system. The one I had installed
injected air into the water entering the iron filter in order to convert
from dissolved iron to red iron which can be filtered out via a (IIRC)
green sand filter.

Just a thought.


Yes I have the same system as you I think...2 slender cylinders with
timers and a trash can sized tank that I add salt to...(green bag) Now
that you mention it I think he said something about injecting air. So
milky water is "normal"????


I assume one of the tanks and the "trash can sized tank" makes up the
softener side of your system.

IF the other tank is indeed your green sand filter, you should need to use
the salt that comes in the green bag. That salt includes the equivalent of
"Iron Out" added to the salt. If the iron filter is working --- and the air
bubbles indicate it is -- you shouldn't have iron reaching your softener.
You should double check with your installer to make sure you understand what
they installed. BTW, my iron filter had an automotive type valve stem
mounted on a device where the water entered the filter. There is a venturi
in the device which created a low pressure zone which sucked the tire valve
open and drew air into the water stream.

As I recall, the air eventually went away. But it's presence should be a
comforting assurance to you that the system is working properly.