Thread
:
Phone wiring
View Single Post
#
25
Posted to alt.home.repair
Jim Redelfs
external usenet poster
Posts: 664
Phone wiring
In article . com,
wrote:
These are gonna be live wires, no?
Yes. -48VDC
(Very little current, but still some.)
So what do I use to handle them?
Your BARE fingers and hands.
We virtually NEVER turn off a POTS (Plain Old Telephone Service) line prior to
working on it.
Unless you are soaking wet and well grounded, you will never feel dial tone
current.
On the other hand, if you are soaking wet and well grounded, and someone RINGS
your line while you are handling the pair, you will get zapped with ~100VAC.
Such risk is minimal and comes with the job.
Working on 22-24-gauge wire with insulated gloves - or ANY gloves for that
matter - is almost impossible. Don't worry about it.
--
JR
Mean Evil Bell System
Historical Society
Reply With Quote
Jim Redelfs
View Public Profile
Find all posts by Jim Redelfs