View Single Post
  #5   Report Post  
Posted to alt.binaries.schematics.electronic
Spehro Pefhany Spehro Pefhany is offline
external usenet poster
 
Posts: 1,475
Default 0th cut, c/esr meter - Meter_0.jpg

On Sun, 15 Jul 2007 16:25:14 -0700, the renowned John Larkin
wrote:


With some decent code, this could measure capacitance (uF range, not
pFs), true esr, resistance, millivolts, possibly a useful range of
inductances. It could find shorted pcb traces and maybe plot diode
curves.

The dac is optional, and the adc might be inside the uP.

This is a stage 0 brainstorm. Of course you can find objections, but
I'd prefer improvements.

John


What's the purpose of the SSR, just to have two ranges of current
source? If so, it might be cheaper and more accurate to have two
sources in parallel.



Best regards,
Spehro Pefhany
--
"it's the network..." "The Journey is the reward"
Info for manufacturers: http://www.trexon.com
Embedded software/hardware/analog Info for designers: http://www.speff.com