Robert Allison wrote in
news:Rkwci.1$Fk7.0@trnddc01:

Al Bundy wrote:
Robert Allison wrote in
news:nV2ci.7546$1o.2395@trnddc01:


Bgreer5050 wrote:

What size of roll flashing would you recommend between the porch
roof and the siding on this elevation?

http://mropartner.com/frontelevation.htm



I don't know about "roll flashing". I am not familiar with
that term. I would use wall angle at that juncture. I like
to have mine custom made and I have it bent with 6" exposed
and 6" up the wall. Cover the wall side with Ice and water
shield sealing the felt or housewrap over the flashing. This
seals any nail holes that you have to make through the siding
and through the flashing.




Gonna have to do a very similar area (first pic) myself when I finish
the main body roof.

Believe he is talking about the flashing material that comes on a
roll various widths 10/14/20",etc. Stuff you bend yourself. I've seen
it in aluminum and galvanized.


Around here we call that valley flashing or coil stock.


'round here too.


Haven't seen it myself but online it seems the Borg has Roll Stock
Vinyl Flashing. Anyone ever use it? Pros or cons?


Would never use vinyl anywhere that is in the sun or needs to
be protected from water intrusion.


That just about leaves indoor use only...


Never dealt with putting it on a house with vinyl siding. I know
there's a tool to pull siding. What about that bottom piece where the
siding meets the roof? Nailed in?


All vinyl siding is nailed loosely (or should be). I have
never had a problem removing it or getting it back on. Just
use a flat bar.



Thanks for the reply...