View Single Post
  #8   Report Post  
Posted to alt.home.repair
Bob M. Bob M. is offline
external usenet poster
 
Posts: 375
Default Hot water heater is really a luke warm heater


wrote in message
oups.com...
I installed a new gas hot water heater and have an annoying problem:
I only have hot water in the morning if I run hot water (ie,
dishwasher) the night before. Otherwise, I have tepid water when no
hot water is used within ten hours or so. If I run hot water in the
morning for a few minutes, and wait ten or fifteen minutes, the heater
kicks on and recovers fairly fast. If I turn the heater up past
"hot", it just dumps hot water out from the overflow. It's like the
heater believes if I'm gone for ten hourse or more, I'm never coming
back. Any ideas?


You're describing exactly the problem I had. Check the cheap things first.
The plastic dip tube - did you put it in and/or is it still there? You have
to take off the cold water supply side and look/feel inside the nipple to
know if the tube is still there (if it ever was).

If it's gone, they're $10 at the local hardware store. That fixed my
problem anyhow.

As others have asked, it's a new tank and already it's out of warranty? How
"new" is this tank?