Default OT : Kerosene space heaters

It should run just fine on #2 diesel. Use it in mine
exclusively. Clean the plug and blow out the nozzle. Also
make sure the ignition TR works.
JR
Dweller in the cellar

habbi wrote:

I have a "Master" Kerosene space heater and the other day I filled it with
diesel thinking it would be a lot cheaper. It worked for a while and then
quite. The blowers still runs and it smells like a mist of diesel is being
made but it does not ignite. First of all can these heaters burn diesel or
strictly kerosene. (the smell is not an issue) Also what has gone wrong with
the ignition system, I assume it is similar to a burner in a furnace or
boiler. Thanks

---
Outgoing mail is certified Virus Free.
Checked by AVG anti-virus system (http://www.grisoft.com).
Version: 6.0.555 / Virus Database: 347 - Release Date: 23/12/2003


--
Remove X to reply

--------------------------------------------------------------
Home Page: http://www.seanet.com/~jasonrnorth
If you're not the lead dog, the view never changes
Doubt yourself, and the real world will eat you alive
The world doesn't revolve around you, it revolves around me
No skeletons in the closet; just decomposing corpses
--------------------------------------------------------------
Dependence is Vulnerability:

"Open the Pod Bay Doors please, Hal"