View Single Post
  #5   Report Post  
Posted to sci.electronics.repair
Homer J Simpson Homer J Simpson is offline
external usenet poster
 
Posts: 1,245
Default 120VAC 15A motor won't spin up to speed


"Michael Kennedy" wrote in message
. ..

I have a 120VAC 15A electric motor that is on an aircompressor that I
found. I plugged it in and the motor starts to spin slowly but never gets
going fast then trips the circuit breaker.

It spins eaisly by hand and the bearings seem to be okay. Does it probably
just need new capacitors? It has 2 120v 330uf caps on it.


If those are the correct ratings, possibly. But I'd check the windings with
a meter first.