F wrote:

I need to move a shaver point from one wall to another and install an
illuminated mirror above it in the bathroom. I assume Part P applies.


Yes - assuming you are in England or Wales and it's a domestic
bathroom.

The present shaver point has a light built in and is wired straight off
the lighting circuit. Would this be acceptable in the new location or
should it be on a fused spur? If so, can the FCU be in the bathroom
close up to the ceiling or must it be outside?


No FCU is required. Shaver supply units can be wired straight into a
lighting circuit.

Make sure that the shaver point contains an isolating transformer as
it is going into a bathroom.

John
--
John White,
Electrical Contractor