Default Grundig TV MFW70-2410/7

In data Sun, 25 Jun 2006 16:33:09 +0200, BRASTO ha
scritto:

When switched on: sound and picture appears. E/W amplitude is too
small, Focus is not correct, HOT T504 (2SC5331) runs very hot, R536
(6.8R 1W) runs very hot. The TVset switches to SBY (protection mode)
after aprox 6 seconds.

When reapplying power the same event happens.

Running the set on a ballast lamp with HOT disconnected shows no
problems, B+ however is believed to be a little low (130 VDC rather
than 148 VDC)

Could the HV transformer be defective ? other suspects ?


Oh, maybe if you say the chassis number...

TIA
Bram




--