View Single Post
  #6   Report Post  
Posted to alt.home.repair
larry
 
Posts: n/a
Default stripped screw hole - conduit box

Wolf wrote:
George wrote:

Wolf wrote:

Options please ... installing an extension box onto an exterior wall
outlet (a weather proof cover will then be attached). The screw that
secures the outlet, also secures the extension box in place. While
securing the second screw I discover that the screw hole on the
conduit box is stripped ... I can not get a tight seal (one one
screw holding) and it will be impossible to get a weather tight seal
on the cover (which is attached to the extension box). The screw
used is a 6 - 32 machine thread 2.5 inches long. Is there a quick fix
...




I have used a #6 self tapping screw in similar situations.


Thanks for all the responses ... unable to find a #6 2.5" self tapping
screw BUT was able to get a #8 ... since the # 6 was a loose fit I
thought I give it a try ... SUCCESS. I was going to tap it but but the
taps I had were too short and I didn't want to disassemble the
conduit(PVC - Rigid). Got everything buttoned up just before the rain
started :-) Thanks again!



Is Dallas the only place that sells 6/32 captive tinnerman
nuts? U shaped spring clip, thread one side, clearance hole
other side. Clip one over the box lip, threaded part to
back of the box.

Didn't read all the posts, but I'm sure drywall screws were
suggested. See a lot of that, nothing like a #6x32 slot
head in one and a #8 or #10 self-tap phillips(dw) in the other.

-larry

"anything worth doing at all is worth doing well" -Ms. Mac
GHS '64 ;-)