View Single Post
  #2   Report Post  
Posted to rec.woodworking
Doug Miller
 
Posts: n/a
Default 220V Magnetic switch problem

In article , Greg D. wrote:
I'm trying to wire my new cabinet saw for 220V. Got the 220V outlet,
installed the power cord onto the magnetic switch on the table saw
exactly as shown in the diagram.

For those interested in the details, I've got a General cabinet saw
(the Canada made one) and connected my power cord to the L1 and L3
screws. Each one gets its 110V of power. The meter reads properly but
it doesn't seem that the power reaches the other side to make the
motor run. I released the stop button and push the green one just to
see nothing. I even pushed the thermal reset button on the motor just
in case and still nothing.

Does anyone here have an idea what to do? Is there any special thing
to do the first time you start it?


Is your 220V circuit wired correctly? That is, do you really have 220V? Check
the voltage between L1 and L3. Do you see 220, or zero?

--
Regards,
Doug Miller (alphageek at milmac dot com)

It's time to throw all their damned tea in the harbor again.