View Single Post
  #7   Report Post  
Posted to alt.home.repair
Tom The Great
 
Posts: n/a
Default Cut hole in cement block load bearing wall for window A/C?

On Sun, 30 Apr 2006 02:11:39 GMT, "Edwin Pawlowski"
wrote:


wrote in message
roups.com...
I have an attached garage with cement block outside wall that I would
like to cut a hole in large enough for a 15,000 - 20,000 btu window
a/c. Feasible??


Sure. I've done it on a few houses. Add a lintel on the top. It is possible
to notch and fit a lintel in place, but you can also cut the opening wider
than what is needed, then put the steel on top and support it with brick
under it. If you can put the hole under a window there is less weight to be
supported also.



Good advice, I've seen this done(with the brick work on the bottom for
a sill), and it looked very nice. Especially if you trim it out, and
hide the lental behind molding.


later,

tom @ www.NoCostAds.com