View Single Post
  #8   Report Post  
Posted to sci.electronics.repair
JazzMan
 
Posts: n/a
Default Before I throw this X-10 lamp module away... Success!

James Sweet wrote:

JazzMan wrote:
jakdedert wrote:

JazzMan wrote:

A bulb blue-flashed failed in my lamp controlled by a
standard X-10 lamp module, the result being that now
the module when turned off only goes to half-brightness,
both by dimming and by commanding OFF via the remote. I
don't have money to buy another one, but may have the
ability to fix this one if it's a known failure mode
and replacement parts are in my giant bin-O-parts.

Anyone know enough about these to offer pointers or
advice?

JazzMan

Triac....

Google it.

jak




Thanks, I would (given my luck) spent a couple of days
googling before I stumbled across a repair. Now to find
a triac.

JazzMan


You can get one at Radio Shack, if you can't find one there, email me
and I'll send you one.


Success!!! I had a dead wall switch module, it quit responding to
the remote a long time ago. I looked at it and it had a triac
similar to the one in the lamp module. It was BTA10 400C, and the
lamp module triac was marked BTA10 600C. It took some finagling
the leads because the center lead was bent opposite on the wall
switch compared to the lamp module, but after getting it in it
worked perfectly. Thanks a bunch, folks!

JazzMan
--
************************************************** ********
Please reply to jsavage"at"airmail.net.
Curse those darned bulk e-mailers!
************************************************** ********
"Rats and roaches live by competition under the laws of