View Single Post
  #8   Report Post  
Posted to uk.d-i-y
meshaw
 
Posts: n/a
Default Slab Insulation 'R' values for tonight.

Liz
the wickes insulation slabs are made to spec by knauf - the knauf
absorption data is as below:
Absorption co - efficients - S = Solid Backing - C = Cavity
Rocksil Slabs
Thickness RS33
125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz NRC
40S 0.16 0.45 0.82 1.00 1.00 1.00 0.82
50S 0.10 0.60 0.90 1.00 1.00 1.00 0.88
60S 0.22 0.75 1.00 1.00 1.00 1.00 0.94
75S 0.24 0.53 0.89 0.94 0.96 0.98 0.83
100S 0.39 1.00 1.00 1.00 1.00 1.00 1.00

Thickness RS45
125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz NRC
25S 0.05 0.25 0.55 0.75 0.9 1.00 0.61
40S 0.14 0.40 0.87 1.00 1.00 1.00 0.82
50S 0.25 0.65 1.05 1.10 1.05 0.95 0.96
75S 0.50 1.05 1.20 1.15 1.10 0.95 1.13
100S 0.80 1.15 1.20 1.15 1.15 1.00 1.16
50C 0.45 0.95 0.80 0.95 0.95 1.00 0.91

Thickness RS60
25S 0.10 0.20 0.65 0.85 1.00 0.90 0.68
40S 0.13 0.49 0.95 1.00 1.00 1.00 0.86
50S 0.25 0.65 1.05 1.10 1.10 0.95 0.98
75S 0.55 1.10 1.20 1.15 1.15 1.05 1.15
50C 0.45 0.90 0.80 0.90 0.95 0.95 0.89

Thickness RS80
25S 0.06 0.23 0.56 0.88 1.00 1.00 0.67
40S 0.14 0.61 1.00 1.00 1.00 1.00 0.90
50S 0.16 0.72 1.00 1.00 1.00 1.00 0.93
60S 0.25 0.90 1.00 1.00 1.00 1.00 0.98
75S 0.39 1.00 1.00 1.00 1.00 1.00 1.00
100S 0.59 1.00 1.00 1.00 1.00 1.00 1.00

Thickness RS100
25S 0.05 0.30 0.70 0.95 1.05 1.00 0.75
40S 0.12 0.44 0.88 1.00 1.00 1.00 0.83
50S 0.35 0.85 1.10 1.10 1.15 1.10 1.05
75S 0.44 1.00 1.00 1.00 1.00 1.00 1.00
50C 0.65 0.95 0.80 0.90 0.95 1.00 0.90

Thickness RS128
125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz NRC
50S 0.40 0.90 1.00 1.00 1.00 0.95 0.98
50C 0.65 0.80 0.85 0.95 0.95 1.00 0.89

Thickness RS140
125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz NRC
50S 0.40 0.90 1.15 1.05 1.10 0.95 1.05
50C 0.65 0.80 0.85 0.95 0.95 1.00 0.89

Thickness RS200
125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz NRC
50S 0.40 0.50 0.70 0.70 0.70 0.70 0.65

Rocksil Insulation Mat
Thickness
125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz NRC
150 0.70 1.20 1.24 1.13 1.14 1.18 1.18
100 0.40 0.88 1.03 0.99 1.06 1.11 0.99
80 0.31 0.83 0.96 0.98 1.04 1.14 0.95
60 0.25 0.60 0.83 0.89 0.96 1.04 0.82

Rocksil Studio Mattress
Thickness
125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz NRC
50S 0.25 0.65 1.05 1.10 1.05 0.95 0.96
50C 0.45 0.95 0.80 0.95 0.95 1.00 0.91
S= Solid Backing - C = cavity
the wickes general purpose slab will probably correlate to RS45
(45kg/m3) 50S (mm)and the heavy density slab to RS200 (yes 200kg/m3)
but at 30mm as oppose to 50mm - i too was very interested to see this
data - as far i can see it basically means the 50mm general purpose
slab, much lower density will perform much better than the 30mm HD slab
with the exception perhaps of the 125hz low frequency.
The best of all for acoustic purpose would be the 85mm cavity wall
slabs which at RS45 appear to be excellent performers, but surprisingly
arent branded by wickes for the particular purposes of acoustic
insulation - they seem to push the heavy density slabs when infact they
arent the best performers, but are quite handy if your after saving an
inch or two!!
cheers
ME Shaw


Liz wrote:
While I am burning the midnight oil I would be really grateful if
someone has the R values for
Wickes 50mm General Purpose Slab Insulation and
Wickes 30mm Heavy Density Slab Insulation.
Thanks if possible,
Liz.