Default Why does two channels of ADC give different outputs?

"Frank" wrote in message
...
Ah! I understand what you mean now. PHY_EN is a stable signal, while my
clock
period is 25ns, in each frame, digital side is sending some 1200 I/Q
samples,
one pair of samples each cycle and unchanged throughout the clock cycle.

From the datasheet of ADC, I don't see there is any Rd or CD signal, it's

as
plain as ADC outputs are hold stable and change every 25ns.


That is correct. The rising edge of ENCa and b (clock) sample the signal and
on the falling edge, a valid word can be read from the databus. So your
analyzer should trigger on the falling edge of the ENC signal


Meindert