Default Are you using a VFD?

On Mon, 28 Nov 2005 20:48:34 -0600, "Mike Henry"
wrote:

The only minor problem was with the Hitachi because the original were
momentary push buttons for start and stop. The Hitachi L-100 lacks the
built-in logic to use this setup directly as it expects a sustained "on"
contact closure. A tech note from Hitachi provided wiring for a small
control relay and diode, which fixed that problem for around $15 at Radio
Shack. I think that this is referred to as "3-wire control" and has the
benfit that a power outage will shut down the motor until power is back up
*and* the start button is depressed again. The drum switches on the lathe
and mill will power either back up when power comes back on unless I
manually turn the switches to off.

Mike


Does your Hitachi make the motor "sing"?

I have one ..about a 2hp..cant recall the model number at the moment
that Id originally put on my drill press, and it made the motor
"sing"....very high note, right at the edge of my (very bad) hearing
range. Almost a hydraulic or servo sound....

I didnt like using it on the drill press, as it required coming to a
full stop before it would allow you to reverse directions, so I stuck
on the old Horizon, saving the Hitachi for another future project.

Gunner

"Pax Americana is a philosophy. Hardly an empire.
Making sure other people play nice and dont kill each other (and us)
off in job lots is hardly empire building, particularly when you give
them self determination under "play nice" rules.

Think of it as having your older brother knock the **** out of you
for torturing the cat." Gunner