Put the heating switch on and see what happens. If the boiler starts
firing on-and-off then the call for heat is reaching the boiler but not
running the pump, in which case either the switches should be
interlocked or the system replumbed/wired to prevent this happening.


But hat doesn't happen, the [pump just runs in heating only mode.


Most simple programmers have the switches for both heating and water fed
via removable links. For a gravity circulation system it's usual to feed
the heating switch off the output from the hot water one so the heating
only option you have with a fully pumped one does nothing on its own.

--