First thing to try is the tuner control IC. I'm not at work right now
to get the exact info, but it's the IC chip in the tuner that solders through the board, not the surface mount one. Very common to be bad. You did use the TAG generator and did the tuner alignment I assume? No chance of having cable reception without tuner alignment after eprom has been fooled with or corrupted by bad connections. |
#2
|
|||
|
|||
Stations all snowy!
Rono wrote:
CTC 177 AG fully repaired the built-in tuner! Reset EEPROM, all seems ok, but most stations, on cable are quite snowy! Ideas? Rono. when you say most stations then you could have a IF problem or an AGC return problem.. |
#3
|
|||
|
|||
Chipper Checker and check E-Prom Data, may require you to realign the tuner.
"Jamie" wrote in message ... Rono wrote: CTC 177 AG fully repaired the built-in tuner! Reset EEPROM, all seems ok, but most stations, on cable are quite snowy! Ideas? Rono. when you say most stations then you could have a IF problem or an AGC return problem.. |
#4
|
|||
|
|||
Art, What do you look for when checking the data? How do you know it is
correct if you don't have the original data from the set? Is there a particular address that you look for? These sets need the tuner wrap resoldered, if it has not been done correctly before. I'd look for solder bridges if it was done then the tuner snowy. Leonard "Art" wrote in message ... Chipper Checker and check E-Prom Data, may require you to realign the tuner. "Jamie" wrote in message ... Rono wrote: CTC 177 AG fully repaired the built-in tuner! Reset EEPROM, all seems ok, but most stations, on cable are quite snowy! Ideas? Rono. when you say most stations then you could have a IF problem or an AGC return problem.. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
ADV: All-Spec Limited Time Sale - $89 Weller Soldering Stations | Electronics | |||
Toshiba CF3062K pix goes snowy then clear | Electronics Repair | |||
GE 25GH350 CTC177AJ2 Snowy channals above 50. | Electronics Repair | |||
Earlex Spray Stations | UK diy | |||
Toshiba CF32G40 (TAC 9705): Won't tune in stations. | Electronics Repair |