UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Ged
 
Posts: n/a
Default Loft conversion - feed the shower?

I am planning a loft conversion and want to put in a shower.

Currently we have a conventional boiler and a ropy old indirect system
with cold tank in loft, hot water tank supplying the family bathroom.
I have put in a shower pump so that the bathroom shower is very
powerful and as a consequence has a very short lifespan before we are
cold showering.

So...... the loft shower. I need to have a decent flow and an endless
supply, so should I
1. put in a combi in th eloft to supply the loft hot water and heat
2. put in an electric shower
3. re-do the current system and replace with....
4. Put insome kind of thermal store or hiogh pressure system
5. do something else?

as you can see, thinking is at early stages and so any advice would be
looked at kindly

cheers
Ged
  #2   Report Post  
Christian McArdle
 
Posts: n/a
Default Loft conversion - feed the shower?

1. put in a combi in th eloft to supply the loft hot water and heat

This is a possiblity if you are replacing the boiler anyway. An
instantaneous non-storage combi will provide excellent showers, but will be
less good filling the bath. This won't be an issue if you mainly take
showers, although you will definitely need a high flow version if you want
both showers to work simultaneously. There are also storage based solutions
with a small unvented cylinder or heat bank within the boiler casing. These
will provide reasonable bath performance, too.

2. put in an electric shower


Choke. Splutter. Cough.

4. Put insome kind of thermal store or hiogh pressure system


I put a DPS Pandora heat bank in. I haven't converted the loft yet, but this
will be ideal when I do.

5. do something else?


You may be able to use the existing hot water system with the right array of
pumps, switches and check valves. The shower would almost certainly need a
"kick start" switch as the head would be negative, so flow switches won't
work (except to keep the system on until you've finished).

Christian.



  #3   Report Post  
David W.E. Roberts
 
Posts: n/a
Default Loft conversion - feed the shower?


"Ged" wrote in message
om...
I am planning a loft conversion and want to put in a shower.

Currently we have a conventional boiler and a ropy old indirect system
with cold tank in loft, hot water tank supplying the family bathroom.
I have put in a shower pump so that the bathroom shower is very
powerful and as a consequence has a very short lifespan before we are
cold showering.

So...... the loft shower. I need to have a decent flow and an endless
supply, so should I
1. put in a combi in th eloft to supply the loft hot water and heat
2. put in an electric shower
3. re-do the current system and replace with....
4. Put insome kind of thermal store or hiogh pressure system
5. do something else?

as you can see, thinking is at early stages and so any advice would be
looked at kindly


Disregarding the loft, it sounds as though you already need a much larger
hot water tank.

We fitted a power shower pump and quickly emptied the hot water, and so had
an extra large copper tank fitted. This now manages to service two power
showers at the same time.

As already posted, your conventional system can work in the loft as long as
you have a way to 'kickstart' the pump.

Beware the 'combi' debate :-)

HTH
Dave R


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Extending CH to loft conversion Ben Freeman UK diy 12 March 11th 04 08:22 PM
Adding CH to new loft - advice please [email protected] UK diy 19 January 7th 04 08:58 AM
shower pump in loft problem advice required Gary Holt UK diy 3 October 2nd 03 01:57 PM
Power to loft. Spur of 60A shower feed? Will Cooke UK diy 1 August 5th 03 12:15 AM