  #1   Report Post  
Crewood
 
Posts: n/a
Default Flushing out a radiator

Hello all,

I have problems with two downstairs radiators, both are cold although
the pipes leading to them are warm. I guess they both need flushing
out. The other radiators on the ground floor are warm.

Can someone please advise how to do this, the radiators have been in
for around 15 years and are the older style without fins in the middle.

Regards....Mike

  #2   Report Post  
Harry Bloomfield
 
Posts: n/a
Default

Crewood brought next idea :
Hello all,

I have problems with two downstairs radiators, both are cold although
the pipes leading to them are warm. I guess they both need flushing
out. The other radiators on the ground floor are warm.

Can someone please advise how to do this, the radiators have been in
for around 15 years and are the older style without fins in the middle.

Regards....Mike


Close the valves at each side, then check by opening the bleed valve
that the valves have managed to seal. Then take the radiator outside
and give it a good flush out both ways until it runs clear.

You can I believe also get heating system flushing solutions which you
add to the entire system.

--

Regards,
Harry (M1BYT) (L)
http://www.ukradioamateur.org

  #3   Report Post  
John Stumbles
 
Posts: n/a
Default

Crewood wrote:
Hello all,

I have problems with two downstairs radiators, both are cold although
the pipes leading to them are warm. I guess they both need flushing
out. The other radiators on the ground floor are warm.


Have they ever worked properly? If so, have you adjusted the valves on
any other radiators between then and now? Are the troublesome rads
getting hot at all (at top or bottom)? It's unusual for a rad to be so
blocked it doesn't heat up at all, but if other rads are connected so
that the path through them is much lower resistance than the ones which
aren't heating up, then all the hot water will go through them instead:
to fix this you need to trun down the valve(s) on whichever other rad(s)
is/are 'stealing' the flow until the flow is balanced between the rads
(see diyfaq.org.uk)
  #4   Report Post  
Crewood
 
Posts: n/a
Default


Hello all,

Thanks for the replies.

John, the radiators have worked OK before, the "not warming up" on the
two radiators has been a recent and gradual process. Nothing has been
touched on the system to make any changes.

Regards....Mike

  #5   Report Post  
Mark
 
Posts: n/a
Default

On 12 Mar 2005 16:12:54 -0800, "Crewood" wrote:


Hello all,

Thanks for the replies.

John, the radiators have worked OK before, the "not warming up" on the
two radiators has been a recent and gradual process. Nothing has been
touched on the system to make any changes.


Did they start to go cold at the top while still being hot at the
bottom? If so then the rad needs bleeding.

If they were hot at the top and cold at the bottom then it's likely to
be full of sludge and need flushing out.

Mark

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Removing A Radiator Nigel Heather UK diy 15 March 1st 05 09:37 PM
Sealed CH Radiator problem Tim Kedwards UK diy 1 January 25th 05 11:45 AM
power flushing Andy Hall UK diy 4 September 9th 03 11:59 PM
Radiator valve to radiator tail coupling Lee Wright UK diy 1 August 22nd 03 10:11 AM
Flushing and treating Central Heating question echo21 UK diy 4 July 27th 03 10:19 AM


All times are GMT +1. The time now is 10:38 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"