Sorry if I've posted this before - I'm easily confused!

I have a single cold water tank in the roof, an indirect hot water
cylinder and a wall mounted Potterton gas boiler.

The central heating pump has a standard 1" pipe into the bottom, and a
converter to a 1/2" pipe at the top. Actually, the pump seems to be
mounted upside down...

Anyway; the bottom, 1" pipe circulates the centrral heating water AND
the water into the cylinder coil. Both the cylinder and the main CH
pipe have electronic valves on them.

The problem: periodically during the day what sounds like a large
volume of air enters the system. The hot water vents into the roof
tank to truly alarming noises.

I've changed the cylinder thermostat; changed the programmer; taken
all the radiators off, flushed them through and refilled the system.
But the problem remains.

Can anybody advise me please?
  #2   Report Post  
Aidan
 
Posts: n/a
Default


Pete wrote:


I have a single cold water tank in the roof


That could be a problem, there's usually a 50ish gallon cold water
storage tank and a 4ish gallon feed & expansion tank for the heating.
Unless the heating is a sealed system; is there a pressure gauge &
filling loop on it?


Too many possibilities to list and it sounds very alarming. I'd
recommend you try to find someone competent to look at it. Quick. And
turn it off until they have.

The hot water vents into the roof
tank to truly alarming noises.


There should be an open vent pipe from the boiler which has an open end
over the F&E tank. If you can find it, does water discharge from this?
The open vent should always be open, i.e., neither of the electric
valves should be able to close it off. Can you figure out the pipework
layout to ensure this is the case?

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On



All times are GMT +1. The time now is 09:25 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"