depth of plasic mains pipe
Can some one please let me know what the recommended depth for plastic mains
water pipe should in the ground and what is the normal O/Dfor this pipe? |
depth of plasic mains pipe
Ian Brown wrote:
Can some one please let me know what the recommended depth for plastic mains water pipe should in the ground We put ours 1m down. I think the minimum is something like 900mm. and what is the normal O/Dfor this pipe? Depends what it's supplying. For a single house 32mm is fine. -- Grunff |
depth of plasic mains pipe
"Ian Brown" wrote in message ... Can some one please let me know what the recommended depth for plastic mains water pipe should in the ground and what is the normal O/Dfor this pipe? From top of pipe to finished ground level Not less than 750mm. Not more than 1350mm |
depth of plasic mains pipe
Grunff wrote:
Ian Brown wrote: Can some one please let me know what the recommended depth for plastic mains water pipe should in the ground Contact your local water authority, they all have slightly different rules, but will happily tell you what diam. pipe and depth. If you are replacing lead then they will do their connection free of charge. You do however need to go through their procedures. -- Please only reply to Newsgroup as emails to this address are deleted on arrival. |
depth of plasic mains pipe
On Tue, 27 Apr 2004 16:52:44 +0100, "Ian Brown"
wrote: Can some one please let me know what the recommended depth for plastic mains water pipe should in the ground and what is the normal O/Dfor this pipe? 2 foot 6 inches Rick |
depth of plasic mains pipe
"Broadback" wrote in message ... Grunff wrote: Ian Brown wrote: Can some one please let me know what the recommended depth for plastic mains water pipe should in the ground Contact your local water authority, they all have slightly different rules, but will happily tell you what diam. pipe and depth. If you are replacing lead then they will do their connection free of charge. You do however need to go through their procedures. Pretty well 700mm all over, but check. |
depth of plasic mains pipe
Broadback wrote:
You do however need to go through their procedures. I didn't. We're on a private supply. -- Grunff |
depth of plasic mains pipe
We were told 750 mm and they suggested 25mm MDPE
when I re-did ours from a new tapping off the street main, which they did FOC and moled it across the road (if we were to go on a meter, which was fine by us) Mid -Southern Water Co Nick |