[email protected] December 14th 04 05:36 PM

Earthing cooker hood
 
I have just fitted a new cooker hood as part of my kitchen rebuild. The
motor inside the hood is double insulated and therefore the cable is 2
core only. Having followed the various discussions on earth bonding in
this group I am trying to assess whether it is sensible to connect the
metal outer of the hood to the earth from the fused spur.

As I see it although only a remote possibility, potentially a fault
could occur at the crimped joint I will be making between the
applicance cable and the cable from the fused spur. This joint will be
concealed in the chimney piece of the hood.

The spur is fed off my new rcd protected ring main.

If interested here is a picture. The morale in the house is improving
as SWMBO can finally see the kitchen taking shape (albeit after 4
months of having to cook in a building site.

http://www.kapture-it.co.uk/show_alb...lbum_id=009789
What does the group think?

Tim


Grunff December 14th 04 05:47 PM

wrote:
I have just fitted a new cooker hood as part of my kitchen rebuild. The
motor inside the hood is double insulated and therefore the cable is 2
core only. Having followed the various discussions on earth bonding in
this group I am trying to assess whether it is sensible to connect the
metal outer of the hood to the earth from the fused spur.

As I see it although only a remote possibility, potentially a fault
could occur at the crimped joint I will be making between the
applicance cable and the cable from the fused spur. This joint will be
concealed in the chimney piece of the hood.

The spur is fed off my new rcd protected ring main.

If interested here is a picture. The morale in the house is improving
as SWMBO can finally see the kitchen taking shape (albeit after 4
months of having to cook in a building site.

http://www.kapture-it.co.uk/show_alb...lbum_id=009789
What does the group think?



My double-insulated hood's instructions explicitly stated that it should
not be earthed.


--
Grunff

Lurch December 14th 04 06:13 PM

On 14 Dec 2004 09:36:34 -0800, strung together
this:

What does the group think?

I think you should only press send once.
Don't earth the cooker hood, have you earthed all your other double
insulated appliances in the house?
--

SJW
Please reply to group or use 'usenet' in email subject

Mike Tomlinson December 14th 04 06:29 PM

In article .com,
writes

What does the group think?


I think you need to learn how to click the mouse button once.

--
Rarely do people communicate; they just take turns talking.
(source unknown)

Lobster December 14th 04 06:43 PM

"Grunff" wrote in message
...
wrote:
I have just fitted a new cooker hood as part of my kitchen rebuild. The
motor inside the hood is double insulated and therefore the cable is 2
core only. Having followed the various discussions on earth bonding in
this group I am trying to assess whether it is sensible to connect the
metal outer of the hood to the earth from the fused spur.

As I see it although only a remote possibility, potentially a fault
could occur at the crimped joint I will be making between the
applicance cable and the cable from the fused spur. This joint will be
concealed in the chimney piece of the hood.

The spur is fed off my new rcd protected ring main.

If interested here is a picture. The morale in the house is improving
as SWMBO can finally see the kitchen taking shape (albeit after 4
months of having to cook in a building site.

http://www.kapture-it.co.uk/show_alb...lbum_id=009789
What does the group think?



My double-insulated hood's instructions explicitly stated that it should
not be earthed.


I think mine did too; but if an installer is putting his own joint in the
cable effectively within the metal casing of the appliance, could that not
over-ride the mfr's instructions?

But isn't the best solution to wire the appliance direct to the FCU, by
replacing (rather than extending) its flex assuming that isn't presently
long enough?

By the way - to the OP - when I asked a question here recently about ducting
for my own hood, I got my wrist slapped for having used 100mm stuff, as I
think you have (from the photo). 125mm is de rigeur for the application, I
gather!

David