I've got to move some of the central heating pipes
tonight/tomorrow and have a combi boiler which says
I should consult a plumber to drain/refill blah blah.
My head says that it can't be that hard...

Drain
======
Turn off boiler
Isolate heating circuit from boiler using the valves
just below the boiler.

Close the valves I stuck in last year that conveniently
isolate the section of pipe I need to work on, minus
one radiator which I'll close the valves on.

Do the work
===========
Stick a hosepipe on the drain valve, and get any water
out of the pipes that feels like coming

Do my work, expecting to get a little wet because the pipes
will still have some water in.

Refilling
=========
Open up all valves.
Turn thermostat *right* down so that boiler does nothing when
I turn it on.
Turn on boiler (but with heating functions off) because it
has a digital pressure readout, so I need it on. Refill
system. Use built in filler loop (Glowworm 30ci plus) to
get up to pressure. Go round and bleed rads and fill up
as necessary.
http://www.glow-worm.co.uk/epower/gw.../30ci-plus.pdf
says there's an auto-air vent on the boiler, so that should
take care of itself.
Turn the thermostat back up.

Questions
=========

Anything wrong with this?

If I don't finish the pipe work then I realise I'll
have to either cap the pipes or sort out my TRVs if
I don't want a flood overnight. Meanwhile, can I run
the boiler with just domestic hot water on, or will it
rely on the heating circuit to dump excess heat in
some circumstances?

Is there any reason I couldn't run the heating with just
the two radiators that are boiler side of where I'll cut
the pipe? My intuition says yes and that this is a silly
question, but I just thought I'd check.




Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Delta method good enough to fail entire A/C system? ComboverFish Home Repair 13 August 3rd 04 11:30 PM
Cleaning/Flushing a pressurise ad sealed CH system Dougie Nisbet UK diy 26 November 1st 03 07:50 PM
Closed system open system raditors Adam Topp UK diy 6 September 16th 03 06:14 PM
Filling sealed heating system. Do I need a flexi pipe? Rob UK diy 3 September 3rd 03 09:12 AM


All times are GMT +1. The time now is 11:43 PM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"