Parking earth wire
On this occasion the back box doesn't have a terminal for earth.
The 2-gang light switch doesn't have one either. I presume I should use a single choc-block connector to connect these CPCs? |
Parking earth wire
On 26/01/2020 15:48, Fredxx wrote:
On this occasion the back box doesn't have a terminal for earth. The 2-gang light switch doesn't have one either. I presume I should use a single choc-block connector to connect these CPCs? Yes. Unless you are posh and want to use a wago. -- Adam |
Parking earth wire
On Sun, 26 Jan 2020 15:48:45 +0000, Fredxx wrote:
On this occasion the back box doesn't have a terminal for earth. The 2-gang light switch doesn't have one either. I presume I should use a single choc-block connector to connect these CPCs? You know we aren't there looking at what you are right? ;-) If you are asking if you can terminate an unused earth wire in a chock-block (to save it getting into a live connector or some such) I'd guess the answer would be 'yes' (and I'd sleeve it as well). ;-) Cheers, T i m |
Parking earth wire
On 26/01/2020 16:00:05, ARW wrote:
On 26/01/2020 15:48, Fredxx wrote: On this occasion the back box doesn't have a terminal for earth. The 2-gang light switch doesn't have one either. I presume I should use a single choc-block connector to connect these CPCs? Yes. Unless you are posh and want to use a wago. Thanks, I've always been able to park the wire before in an allocated terminal. I guess this is called progress! |
Parking earth wire
On 26/01/2020 16:16:32, T i m wrote:
On Sun, 26 Jan 2020 15:48:45 +0000, Fredxx wrote: On this occasion the back box doesn't have a terminal for earth. The 2-gang light switch doesn't have one either. I presume I should use a single choc-block connector to connect these CPCs? You know we aren't there looking at what you are right? ;-) If you are asking if you can terminate an unused earth wire in a chock-block (to save it getting into a live connector or some such) I'd guess the answer would be 'yes' (and I'd sleeve it as well). ;-) Thanks, I always sleeve bare wires. I just feel a connector in a back box is a cheesy thing to see. |
Parking earth wire
In article , Fredxx wrote:
On 26/01/2020 16:16:32, T i m wrote: On Sun, 26 Jan 2020 15:48:45 +0000, Fredxx wrote: On this occasion the back box doesn't have a terminal for earth. The 2-gang light switch doesn't have one either. I presume I should use a single choc-block connector to connect these CPCs? You know we aren't there looking at what you are right? ;-) If you are asking if you can terminate an unused earth wire in a chock-block (to save it getting into a live connector or some such) I'd guess the answer would be 'yes' (and I'd sleeve it as well). ;-) Thanks, I always sleeve bare wires. I just feel a connector in a back box is a cheesy thing to see. you used to be able to buy earth terminals to add to back boxes (perhaps you still can). I've still got a few. Fine for surface mounted kit, but a bit difficult to retro-fit on stuff that's nicely plastered in. -- from KT24 in Surrey, England "I'd rather die of exhaustion than die of boredom" Thomas Carlyle |
Parking earth wire
On Sun, 26 Jan 2020 16:25:58 +0000, Fredxx wrote:
snip If you are asking if you can terminate an unused earth wire in a chock-block (to save it getting into a live connector or some such) I'd guess the answer would be 'yes' (and I'd sleeve it as well). ;-) Thanks, I always sleeve bare wires. I just feel a connector in a back box is a cheesy thing to see. Whilst I agree (and there are potentially 'tidyer' alternatives), who apart from you is going to see it? And who (other than you) might see it and think anything negative? As long as it's safe, (ideally) to code and as neat as you can make it, ITRW I think that's all you (we) really need? Cheers, T i m |
Parking earth wire
Leans on old gnarled walking stick...
One used to be able to get a blind terminal for earths that one could fix to the bottom of the box with a screw. Maybe they were not considered safe or something if its plastic and broke. My switch boxes in the walls are all metal, now the cleaner discharges her static on all the securing screws! Brian -- ----- -- This newsgroup posting comes to you directly from... The Sofa of Brian Gaff... Blind user, so no pictures please Note this Signature is meaningless.! "Fredxx" wrote in message ... On this occasion the back box doesn't have a terminal for earth. The 2-gang light switch doesn't have one either. I presume I should use a single choc-block connector to connect these CPCs? |
Parking earth wire
On 26/01/2020 17:23, T i m wrote:
On Sun, 26 Jan 2020 16:25:58 +0000, Fredxx wrote: snip If you are asking if you can terminate an unused earth wire in a chock-block (to save it getting into a live connector or some such) I'd guess the answer would be 'yes' (and I'd sleeve it as well). ;-) Thanks, I always sleeve bare wires. I just feel a connector in a back box is a cheesy thing to see. Whilst I agree (and there are potentially 'tidyer' alternatives), who apart from you is going to see it? And who (other than you) might see it and think anything negative? As long as it's safe, (ideally) to code and as neat as you can make it, ITRW I think that's all you (we) really need? Whilst there is a regs requirement that unused earth wires are "terminated"[1], its perhaps more important to keep in mind there will be cases where there are more than one cable entering the switch enclosure, so earth *continuity* must be provided between the CPCs of the cables - hence the terminal takes on more importance. [1] and not just folded back inside some sleeving as I will admit to having done... -- Cheers, John. /================================================== ===============\ | Internode Ltd - http://www.internode.co.uk | |-----------------------------------------------------------------| | John Rumm - john(at)internode(dot)co(dot)uk | \================================================= ================/ |