Home |
Search |
Today's Posts |
|
UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions. |
Reply |
|
LinkBack | Thread Tools | Display Modes |
#1
Posted to uk.d-i-y
|
|||
|
|||
Frustrations arising from adding a second door bell
On Saturday, 27 October 2018 17:40:52 UTC+1, wrote:
On Saturday, 27 October 2018 16:43:46 UTC+1, PaulS wrote: My next thought was that it might be something to do with the way the bell mechanisms work - making and breaking the circuit and that being out of sync in such a way as to prevent either bell from working - so I modified the circuit and added a 12VAC relay. With the relay, where is the additional bell getting its current from? Trembler bells wired in series will *not* work. The 'standard' way to run trembler bells in series is to short the interrupter contacts on the second bell(s). Thus both bells respond to the make-and-break generated by the first bell's interrupter. https://link.springer.com/chapter/10...349-02087-4_12 You may need to add a snubber across the first bell's interrupter as it'll be handling a larger than intended inductive load. I prefer Friedland or Gent bells to Byron. Owain Hi Owain, I'm using the original 8 vac transformer to drive the second bell - at least I would if I'd got as far a getting the first bell and relay in series to work. Thanks for the reference - I'll try shorting the trembler circuit. On the subject of the snubber - any recommendations re a value here? |
#2
Posted to uk.d-i-y
|
|||
|
|||
Frustrations arising from adding a second door bell
On Monday, 29 October 2018 14:39:22 UTC, PaulS wrote:
On Saturday, 27 October 2018 17:40:52 UTC+1, wrote: On Saturday, 27 October 2018 16:43:46 UTC+1, PaulS wrote: My next thought was that it might be something to do with the way the bell mechanisms work - making and breaking the circuit and that being out of sync in such a way as to prevent either bell from working - so I modified the circuit and added a 12VAC relay. With the relay, where is the additional bell getting its current from? Trembler bells wired in series will *not* work. The 'standard' way to run trembler bells in series is to short the interrupter contacts on the second bell(s). Thus both bells respond to the make-and-break generated by the first bell's interrupter. https://link.springer.com/chapter/10...349-02087-4_12 You may need to add a snubber across the first bell's interrupter as it'll be handling a larger than intended inductive load. I prefer Friedland or Gent bells to Byron. Owain Hi Owain, I'm using the original 8 vac transformer to drive the second bell - at least I would if I'd got as far a getting the first bell and relay in series to work. I don't know if you mean the relay coil in series with bell 1 - if so you'd need to rewind the relay coil with much thicker wire for that to work. Thanks for the reference - I'll try shorting the trembler circuit. On the subject of the snubber - any recommendations re a value here? no need. Your existing system proves that Anyway, you've already had explained the standard solution. NT |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Frustrations arising from adding a second door bell | UK diy | |||
Frustrations arising from adding a second door bell | UK diy | |||
Frustrations arising from adding a second door bell | UK diy | |||
Frustrations arising from adding a second door bell | UK diy | |||
Frustrations arising from adding a second door bell | UK diy |