Can anyone help please?
I'm totally in the dark when it comes to central heating systems, so any help would be most grateful. Swift Flow 80 Combi Boiler with Honeywell control. The problem is that I can only get intermittent hot water supply through the taps, sometimes it comes through hot but most of the time it's cold. However, if I leave the central heating on, or switch it on, the hot water is fine. The system is approx. 5yrs old. It's never been serviced (to my shame, probably why I've got problems now) I had to replace the fan impeller and motor a couple of years ago. Water pressure gauge seems ok Thanks, Richard |
#2
|
|||
|
|||
Swift Flow 80 Combi Boiler Problem
"Richard" wrote in message ... Can anyone help please? I'm totally in the dark when it comes to central heating systems, so any help would be most grateful. Swift Flow 80 Combi Boiler with Honeywell control. The problem is that I can only get intermittent hot water supply through the taps, sometimes it comes through hot but most of the time it's cold. However, if I leave the central heating on, or switch it on, the hot water is fine. The system is approx. 5yrs old. It's never been serviced (to my shame, probably why I've got problems now) I had to replace the fan impeller and motor a couple of years ago. Water pressure gauge seems ok Thanks, Richard I have just had the same problem with my c/heating boiler. Ravenheat (bagsh1te) This was the diverter valve. Inside the valve there is a rubber diaphram, which can be replaced usually. I replaced mine with another used one as a temp job, but the rest of the valve had seized,and I have had to replace the whole valve. cost me about £130. diaphrams are about £18-£30. This is not a job for a novice, however seasoned diy'ers could do it ok , with the correct knowledge. Because my boiler had had no work on it for 4 years, when I came to do the job, I got leaks on the pump, through vibrations when taking valve out. Had to get new pump seals. also the isolation valves started to leak and I had to replace them too.. Look on the web for cheaper valves, I found out later, the valve was £55 p/vat on the web. Havent had chance to call them to check if this was the same valve. gutted when I found out. this is the e-mail address for the spares. they have a web site too but cant find it at the moment. rob |
#3
|
|||
|
|||
Swift Flow 80 Combi Boiler Problem
"rob" wrote in message ... "Richard" wrote in message ... Can anyone help please? I'm totally in the dark when it comes to central heating systems, so any help would be most grateful. Swift Flow 80 Combi Boiler with Honeywell control. The problem is that I can only get intermittent hot water supply through the taps, sometimes it comes through hot but most of the time it's cold. However, if I leave the central heating on, or switch it on, the hot water is fine. The system is approx. 5yrs old. It's never been serviced (to my shame, probably why I've got problems now) I had to replace the fan impeller and motor a couple of years ago. Water pressure gauge seems ok Thanks, Richard I have just had the same problem with my c/heating boiler. Ravenheat (bagsh1te) This was the diverter valve. Inside the valve there is a rubber diaphram, which can be replaced usually. I replaced mine with another used one as a temp job, but the rest of the valve had seized,and I have had to replace the whole valve. cost me about £130. diaphrams are about £18-£30. This is not a job for a novice, however seasoned diy'ers could do it ok , with the correct knowledge. Because my boiler had had no work on it for 4 years, when I came to do the job, I got leaks on the pump, through vibrations when taking valve out. Had to get new pump seals. also the isolation valves started to leak and I had to replace them too.. Look on the web for cheaper valves, I found out later, the valve was £55 p/vat on the web. Havent had chance to call them to check if this was the same valve. gutted when I found out. £45 + VAT at BES. |
#4
|
|||
|
|||
Swift Flow 80 Combi Boiler Problem
"IMM" wrote in message ... "rob" wrote in message ... "Richard" wrote in message ... Can anyone help please? I'm totally in the dark when it comes to central heating systems, so any help would be most grateful. Swift Flow 80 Combi Boiler with Honeywell control. The problem is that I can only get intermittent hot water supply through the taps, sometimes it comes through hot but most of the time it's cold. However, if I leave the central heating on, or switch it on, the hot water is fine. The system is approx. 5yrs old. It's never been serviced (to my shame, probably why I've got problems now) I had to replace the fan impeller and motor a couple of years ago. Water pressure gauge seems ok Thanks, Richard I have just had the same problem with my c/heating boiler. Ravenheat (bagsh1te) This was the diverter valve. Inside the valve there is a rubber diaphram, which can be replaced usually. I replaced mine with another used one as a temp job, but the rest of the valve had seized,and I have had to replace the whole valve. cost me about £130. diaphrams are about £18-£30. This is not a job for a novice, however seasoned diy'ers could do it ok , with the correct knowledge. Because my boiler had had no work on it for 4 years, when I came to do the job, I got leaks on the pump, through vibrations when taking valve out. Had to get new pump seals. also the isolation valves started to leak and I had to replace them too.. Look on the web for cheaper valves, I found out later, the valve was £55 p/vat on the web. Havent had chance to call them to check if this was the same valve. gutted when I found out. £45 + VAT at BES. suicidal now, thanks ( rob what does BES stand for and have they got a web site ?? |