stuart noble March 27th 18 09:46 AM

flexi hose
 
Used flexi connectors for kitchen taps about 5 years ago. Yesterday hot side split and flooded kitchen. Seems they're no better than a shower hose then?Mind boggles as to what might have happened if we had been away. Obviously now I won't go anywhere without turning off the stopcock.
Obvious question. Are there higher rated versions able to withstand hot water? Should they be used at all?

Tim Lamb[_2_] March 27th 18 11:18 AM

flexi hose
 
In message ,
stuart noble writes
Used flexi connectors for kitchen taps about 5 years ago. Yesterday hot
side split and flooded kitchen. Seems they're no better than a shower
hose then?Mind boggles as to what might have happened if we had been
away. Obviously now I won't go anywhere without turning off the stopcock.
Obvious question. Are there higher rated versions able to withstand hot
water? Should they be used at all?


They do seem ubiquitous:-(

This is rather concerning as I am about to fit a dozen or so on a
pressurised system.

Is there much of a choice on quality? SF/TS or reputable plumbing
outlet?

--
Tim Lamb

John Rumm March 27th 18 11:41 AM

flexi hose
 
On 27/03/2018 09:46, stuart noble wrote:
Used flexi connectors for kitchen taps about 5 years ago. Yesterday hot side split and flooded kitchen. Seems they're no better than a shower hose then?Mind boggles as to what might have happened if we had been away. Obviously now I won't go anywhere without turning off the stopcock.
Obvious question. Are there higher rated versions able to withstand hot water? Should they be used at all?


Its important to not damage them on installation - so not kinking or
twisting the flexi bit too much.


--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/

GB March 27th 18 01:08 PM

flexi hose
 
On 27/03/2018 11:41, John Rumm wrote:
On 27/03/2018 09:46, stuart noble wrote:
Used flexi connectors for kitchen taps about 5 years ago. Yesterday
hot side split and flooded kitchen. Seems they're no better than a
shower hose then?Mind boggles as to what might have happened if we had
been away. Obviously now I won't go anywhere without turning off the
stopcock.
Obvious question. Are there higher rated versions able to withstand
hot water? Should they be used at all?


Its important to not damage them on installation - so not kinking or
twisting the flexi bit too much.



Looking at the JG Speedfit spec, max temp is 65C. I'm not quite sure
what temp our hot water is, but it must be close to 65C. Anyway, I'm not
surprised that it was the OP's hot water side that split rather than cold.

You could try these:

https://www.plumbcenter.co.uk/produc...lexible-hoses/

They are designed for central heating systems, so ought to survive hot
water.

Mr Pounder Esquire March 27th 18 04:22 PM

flexi hose
 
stuart noble wrote:
Used flexi connectors for kitchen taps about 5 years ago. Yesterday
hot side split and flooded kitchen. Seems they're no better than a
shower hose then?Mind boggles as to what might have happened if we
had been away. Obviously now I won't go anywhere without turning off
the stopcock.
Obvious question. Are there higher rated versions able to withstand
hot water? Should they be used at all?


New kitchen fitted pushing 10 years ago.
After 4 years a hose split under the sink and made a right mess. We are
insured for leaks - not my idea. Out comes plumber and replaced both hoses.
Both were kinked, other one was not far off splitting.
Bloody kitchen fitters!



ss March 27th 18 06:13 PM

flexi hose
 
On 27/03/2018 13:08, GB wrote:
On 27/03/2018 11:41, John Rumm wrote:
On 27/03/2018 09:46, stuart noble wrote:
Used flexi connectors for kitchen taps about 5 years ago. Yesterday
hot side split and flooded kitchen. Seems they're no better than a
shower hose then?Mind boggles as to what might have happened if we
had been away. Obviously now I won't go anywhere without turning off
the stopcock.
Obvious question. Are there higher rated versions able to withstand
hot water? Should they be used at all?


Its important to not damage them on installation - so not kinking or
twisting the flexi bit too much.



Looking at the JG Speedfit spec, max temp is 65C. I'm not quite sure
what temp our hot water is, but it must be close to 65C. Anyway, I'm not
surprised that it was the OP's hot water side that split rather than cold.

You could try these:

https://www.plumbcenter.co.uk/produc...lexible-hoses/

They are designed for central heating systems, so ought to survive hot
water.


At £63 a hose!

ss March 27th 18 06:14 PM

flexi hose
 
On 27/03/2018 16:22, Mr Pounder Esquire wrote:
stuart noble wrote:
Used flexi connectors for kitchen taps about 5 years ago. Yesterday
hot side split and flooded kitchen. Seems they're no better than a
shower hose then?Mind boggles as to what might have happened if we
had been away. Obviously now I won't go anywhere without turning off
the stopcock.
Obvious question. Are there higher rated versions able to withstand
hot water? Should they be used at all?


New kitchen fitted pushing 10 years ago.
After 4 years a hose split under the sink and made a right mess. We are
insured for leaks - not my idea. Out comes plumber and replaced both hoses.
Both were kinked, other one was not far off splitting.
Bloody kitchen fitters!


In Turkey they use flexi hoses, I dont know about quality but people
that owned property replaced them every 3 years as a matter of course.

alan_m March 27th 18 06:24 PM

flexi hose
 
On 27/03/2018 13:08, GB wrote:
On 27/03/2018 11:41, John Rumm wrote:



Looking at the JG Speedfit spec, max temp is 65C. I'm not quite sure
what temp our hot water is, but it must be close to 65C. Anyway, I'm not
surprised that it was the OP's hot water side that split rather than cold.


They specify 65C for flexi connectors with plastic ends (pushfit or
nuts) and 85C for some of their flexi connectors with metal nuts on the
ends.


--
mailto : news {at} admac {dot} myzen {dot} co {dot} uk

stuart noble March 27th 18 08:27 PM

flexi hose
 
Yes £63 but for a pair. Toolstation a fraction of that price. Get what you pay for? Who knows?

Mr Pounder Esquire March 27th 18 09:25 PM

flexi hose
 
ss wrote:
On 27/03/2018 16:22, Mr Pounder Esquire wrote:
stuart noble wrote:
Used flexi connectors for kitchen taps about 5 years ago. Yesterday
hot side split and flooded kitchen. Seems they're no better than a
shower hose then?Mind boggles as to what might have happened if we
had been away. Obviously now I won't go anywhere without turning off
the stopcock.
Obvious question. Are there higher rated versions able to withstand
hot water? Should they be used at all?


New kitchen fitted pushing 10 years ago.
After 4 years a hose split under the sink and made a right mess. We
are insured for leaks - not my idea. Out comes plumber and replaced
both hoses. Both were kinked, other one was not far off splitting.
Bloody kitchen fitters!


In Turkey they use flexi hoses, I dont know about quality but people
that owned property replaced them every 3 years as a matter of course.


I have very big hands that just will not reach behind the kitchen sink. I
tried it.
I understand that flexi hoses are feeding the bath taps, fitted by a
respected
heating engineer. I'm not inclined to take the bath panel out to replace the
hoses.




Rednadnerb March 28th 18 08:16 AM

flexi hose
 
I had the same thing happen on a bath hot water feed after 4 years use. 1st floor flat, made a mess.
I now replace them at the first signs of discoloration and get them from Wickes because their website says they are WRAS approved (although this is not stamped on the product or printed on the packaging - so I have my doubts) rather than from Screwfix because they are not WRAS approved.

stuart noble March 28th 18 10:04 AM

flexi hose
 
On Wednesday, March 28, 2018 at 8:16:30 AM UTC+1, Rednadnerb wrote:
I had the same thing happen on a bath hot water feed after 4 years use. 1st floor flat, made a mess.
I now replace them at the first signs of discoloration and get them from Wickes because their website says they are WRAS approved (although this is not stamped on the product or printed on the packaging - so I have my doubts) rather than from Screwfix because they are not WRAS approved.


Even the named brands that are WRAS approved are similar in price to SF etc..

I wonder about John Rumm's comment re twisting and kinking. As this was a d-i-y job, always tricky under a sink, that could have been a factor. Well, now it's a g-s-i job as hands and knees working is out for me.

Rednadnerb March 28th 18 10:41 AM

flexi hose
 
On Wednesday, March 28, 2018 at 10:04:09 AM UTC+1, stuart noble wrote:
On Wednesday, March 28, 2018 at 8:16:30 AM UTC+1, Rednadnerb wrote:
I had the same thing happen on a bath hot water feed after 4 years use. 1st floor flat, made a mess.
I now replace them at the first signs of discoloration and get them from Wickes because their website says they are WRAS approved (although this is not stamped on the product or printed on the packaging - so I have my doubts) rather than from Screwfix because they are not WRAS approved.


Even the named brands that are WRAS approved are similar in price to SF etc.

I wonder about John Rumm's comment re twisting and kinking. As this was a d-i-y job, always tricky under a sink, that could have been a factor. Well, now it's a g-s-i job as hands and knees working is out for me.


There was no twisting or kinking but I did suspect a leak around the bath mixer, not enough to drip onto the floor but the braiding was rusted through in places.

stuart noble March 28th 18 01:59 PM

flexi hose
 
On Wednesday, March 28, 2018 at 10:41:10 AM UTC+1, Rednadnerb wrote:
On Wednesday, March 28, 2018 at 10:04:09 AM UTC+1, stuart noble wrote:
On Wednesday, March 28, 2018 at 8:16:30 AM UTC+1, Rednadnerb wrote:
I had the same thing happen on a bath hot water feed after 4 years use. 1st floor flat, made a mess.
I now replace them at the first signs of discoloration and get them from Wickes because their website says they are WRAS approved (although this is not stamped on the product or printed on the packaging - so I have my doubts) rather than from Screwfix because they are not WRAS approved.


Even the named brands that are WRAS approved are similar in price to SF etc.

I wonder about John Rumm's comment re twisting and kinking. As this was a d-i-y job, always tricky under a sink, that could have been a factor. Well, now it's a g-s-i job as hands and knees working is out for me.


There was no twisting or kinking but I did suspect a leak around the bath mixer, not enough to drip onto the floor but the braiding was rusted through in places.


Oh, you mean the stainless steel braid! :-)


Rednadnerb March 28th 18 02:20 PM

flexi hose
 
China's finest!

Andrew Gabriel March 28th 18 07:23 PM

flexi hose
 
In article ,
Rednadnerb writes:
I had the same thing happen on a bath hot water feed after 4 years use. 1st=
floor flat, made a mess.
I now replace them at the first signs of discoloration and get them from Wi=
ckes because their website says they are WRAS approved (although this is no=
t stamped on the product or printed on the packaging - so I have my doubts)=
rather than from Screwfix because they are not WRAS approved.


I think the WRAS approval relates to not growing a microbio
film on the inside of the hose which can harbour legionella,
and not so much about longevity or leaking.

--
Andrew Gabriel
[email address is not usable -- followup in the newsgroup]

alan_m March 29th 18 12:06 AM

flexi hose
 
On 28/03/2018 19:23, Andrew Gabriel wrote:
In article ,
Rednadnerb writes:
I had the same thing happen on a bath hot water feed after 4 years use. 1st=
floor flat, made a mess.
I now replace them at the first signs of discoloration and get them from Wi=
ckes because their website says they are WRAS approved (although this is no=
t stamped on the product or printed on the packaging - so I have my doubts)=
rather than from Screwfix because they are not WRAS approved.


I think the WRAS approval relates to not growing a microbio
film on the inside of the hose which can harbour legionella,
and not so much about longevity or leaking.


https://www.wras.co.uk/downloads/pub..._jan_2011.pdf/

--
mailto : news {at} admac {dot} myzen {dot} co {dot} uk

stuart noble March 29th 18 12:33 PM

flexi hose
 
On Thursday, March 29, 2018 at 12:06:14 AM UTC+1, alan_m wrote:
On 28/03/2018 19:23, Andrew Gabriel wrote:
In article ,
Rednadnerb writes:
I had the same thing happen on a bath hot water feed after 4 years use.. 1st=
floor flat, made a mess.
I now replace them at the first signs of discoloration and get them from Wi=
ckes because their website says they are WRAS approved (although this is no=
t stamped on the product or printed on the packaging - so I have my doubts)=
rather than from Screwfix because they are not WRAS approved.


I think the WRAS approval relates to not growing a microbio
film on the inside of the hose which can harbour legionella,
and not so much about longevity or leaking.


https://www.wras.co.uk/downloads/pub..._jan_2011.pdf/

--
mailto : news {at} admac {dot} myzen {dot} co {dot} uk


At SF I can't pay over a fiver for a 300mm hose, so I guess branded and unbranded are all pretty much the same, and presumably all stainless.....? The failure on mine I have to put down to kinking. I did the taps, then pushed the unit back to the wall, during the course of which it's conceivable the edpm got twisted. Bad move in retrospect

alan_m March 29th 18 12:56 PM

flexi hose
 
On 29/03/2018 12:33, stuart noble wrote:

At SF I can't pay over a fiver for a 300mm hose, so I guess branded and unbranded are all pretty much the same, and presumably all stainless.....? The failure on mine I have to put down to kinking. I did the taps, then pushed the unit back to the wall, during the course of which it's conceivable the edpm got twisted. Bad move in retrospect


There is also possibility if the tap and fixed pipe are not in line and
you use a flexi that is just long enough.


--
mailto : news {at} admac {dot} myzen {dot} co {dot} uk

Rednadnerb March 29th 18 01:13 PM

flexi hose
 
On Tuesday, March 27, 2018 at 11:19:00 AM UTC+1, Tim Lamb wrote:

stuart noble
Used flexi connectors for kitchen taps about 5 years ago. Yesterday hot
side split and flooded kitchen. Seems they're no better than a shower
hose then?Mind boggles as to what might have happened if we had been
away. Obviously now I won't go anywhere without turning off the stopcock..
Obvious question. Are there higher rated versions able to withstand hot
water? Should they be used at all?


They do seem ubiquitous:-(

This is rather concerning as I am about to fit a dozen or so on a
pressurised system.

Is there much of a choice on quality? SF/TS or reputable plumbing
outlet?

--
Tim Lamb


Selco's April special offer: 300mm Flexitap connectors with isolating valve.. £1.99 + vat.