#1
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Hi
I've just had an slimline blanced flue inset gas fire installed (Stdio 2 from https://www.stovax.com/stove-fire/st...ine-gas-fires/ ) It required a new hole around 90cm * 45cm to be fitted into (no chimney involved) - the work was surveyed by the fire company and performed by a Gas Safe registered installer and the fire works just fine. A small vertical hairline crack has appeared in the existing wall which runs all the way to the ceiling - I'm pretty sure no lintel was installed but I wasn't around when it was installed. Should it have been? The interior wall is standard breeze block so there would only be a couple of entire blocks hovering above the space. The fire won't be load bearing but the above wall goes all the way the the apex of the house, so a good 6-7m? So - should a lintel have been inserted as part of the job? Gavin |
#2
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On 04/02/2018 20:49, Gavinda Jaya Jaya wrote:
Hi I've just had an slimline blanced flue inset gas fire installed (Stdio 2 from https://www.stovax.com/stove-fire/st...ine-gas-fires/ ) It required a new hole around 90cm * 45cm to be fitted into (no chimney involved) - the work was surveyed by the fire company and performed by a Gas Safe registered installer and the fire works just fine. A small vertical hairline crack has appeared in the existing wall which runs all the way to the ceiling - I'm pretty sure no lintel was installed but I wasn't around when it was installed. Should it have been? The interior wall is standard breeze block so there would only be a couple of entire blocks hovering above the space. The fire won't be load bearing but the above wall goes all the way the the apex of the house, so a good 6-7m? So - should a lintel have been inserted as part of the job? Gavin Yes. -- Cheers, Roger ____________ Please reply to Newsgroup. Whilst email address is valid, it is seldom checked. |
#3
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On 04/02/2018 20:49, Gavinda Jaya Jaya wrote:
Hi I've just had an slimline blanced flue inset gas fire installed (Stdio 2 from https://www.stovax.com/stove-fire/st...ine-gas-fires/ ) It required a new hole around 90cm * 45cm to be fitted into (no chimney involved) - the work was surveyed by the fire company and performed by a Gas Safe registered installer and the fire works just fine. Assuming the 90cm is the width, then that is wider than a standard door, and that would usually have a lintel. So - should a lintel have been inserted as part of the job? Seems pretty likely. (45cm on a block wall would be less of an issue) -- Cheers, John. /================================================== ===============\ | Internode Ltd - http://www.internode.co.uk | |-----------------------------------------------------------------| | John Rumm - john(at)internode(dot)co(dot)uk | \================================================= ================/ |
#4
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
John Rumm wrote:
On 04/02/2018 20:49, Gavinda Jaya Jaya wrote: Hi I've just had an slimline blanced flue inset gas fire installed (Stdio 2 from https://www.stovax.com/stove-fire/st...slimline-gas-f ires/ ) It required a new hole around 90cm * 45cm to be fitted into (no chimney involved) - the work was surveyed by the fire company and performed by a Gas Safe registered installer and the fire works just fine. Assuming the 90cm is the width, then that is wider than a standard door, and that would usually have a lintel. So - should a lintel have been inserted as part of the job? Seems pretty likely. (45cm on a block wall would be less of an issue) It's perhaps worth pointing out that minor cracking is quite likely even if it does have a satisfactory lintel. Provided it does not get any bigger it is probably fine to just fill it. As far as a lintel is concerned, the OP could ask the people who did it, test with a magnet (although the lintel might not be steel) or if all else fails cut a strip out of the plaster to check. -- Roger Hayter |
#5
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On 05/02/2018 01:33, Roger Hayter wrote:
John Rumm wrote: On 04/02/2018 20:49, Gavinda Jaya Jaya wrote: Hi I've just had an slimline blanced flue inset gas fire installed (Stdio 2 from https://www.stovax.com/stove-fire/st...slimline-gas-f ires/ ) It required a new hole around 90cm * 45cm to be fitted into (no chimney involved) - the work was surveyed by the fire company and performed by a Gas Safe registered installer and the fire works just fine. Assuming the 90cm is the width, then that is wider than a standard door, and that would usually have a lintel. So - should a lintel have been inserted as part of the job? Seems pretty likely. (45cm on a block wall would be less of an issue) It's perhaps worth pointing out that minor cracking is quite likely even if it does have a satisfactory lintel. Provided it does not get any bigger it is probably fine to just fill it. As far as a lintel is concerned, the OP could ask the people who did it, test with a magnet (although the lintel might not be steel) or if all else fails cut a strip out of the plaster to check. As Roger says, even if they have fitted a lintel- which I would expect- small cracks are not uncommon after such work. If nothing else, the heat from the new fire may have contributed to it. I'm not so sure re a magnet- even a decent cover of render and plaster will probably be enough to mean the distance between the surface of the wall and the lintel is too big for a magnet to work. I'd try a stud finder. While these are designed to detect wood behind plasterboard, they do detect other things. I've used mine to detect wood behind a metal skinned, 50mm insulated, motorhome body. Try first somewhere you known there is/should be a lintel. -- Suspect someone is claiming a benefit under false pretences? Incapacity Benefit or Personal Independence Payment when they don't need it? They are depriving those in real need! https://www.gov.uk/report-benefit-fraud |
#7
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Gavinda Jaya Jaya formulated the question :
A small vertical hairline crack has appeared in the existing wall which runs all the way to the ceiling - I'm pretty sure no lintel was installed but I wasn't around when it was installed. Should it have been? The interior wall is standard breeze block so there would only be a couple of entire blocks hovering above the space. Most certainly, there should have been a lintel installed. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
How to make sure lintel is safely / correctly installed? | UK diy | |||
Natural Gas - Pictures and Diagrams of Natural Gas, Natural Gas Furnace, Natural Gas Grill, Natural Gas Heater, Natural Gas Water Heater and Natural Gas Vehicle | Home Ownership | |||
Natural Gas - Pictures and Diagrams of Natural Gas, Natural Gas Furnace, Natural Gas Grill, Natural Gas Heater, Natural Gas Water Heater and Natural Gas Vehicle | Home Repair | |||
Turning 'Til There's No There There | Woodturning | |||
Gas Fire - Fire basket and gas engine or just a simple Valor gas fire? | UK diy |