TN-C-S with additional earth rod
My house supply is TN-C-S but also has an earth rod. It's a dedicated
supply that runs overhead for some distance before diving underground to get into the house. An earth rod with PME seems to be controversial but I can't see any downside for an isolated property. Have I missed anything? |
#2
Posted to uk.d-i-y
|
|||
|
|||
TN-C-S with additional earth rod
|
#3
Posted to uk.d-i-y
|
|||
|
|||
TN-C-S with additional earth rod
wrote:
My house supply is TN-C-S but also has an earth rod. It's a dedicated supply that runs overhead for some distance before diving underground to get into the house. An earth rod with PME seems to be controversial but I can't see any downside for an isolated property. Have I missed anything? The outside connection to the earth rod should be mechanically protected and insulated from being touched. It should have decent size of wire connecting it directly ot the main earth terminal by the incoming main fuse. There shouldn't be any additional connections to it except via the house wiring. Then I can't see what harm it could do (others might!) but don't rely on it to alter the characteristics of the TN-C-S installation. -- Roger Hayter |
#4
Posted to uk.d-i-y
|
|||
|
|||
TN-C-S with additional earth rod
On 30/09/2017 11:33, wrote:
My house supply is TN-C-S but also has an earth rod. It's a dedicated supply that runs overhead for some distance before diving underground to get into the house. An earth rod with PME seems to be controversial but I can't see any downside for an isolated property. Have I missed anything? No not really. The earth rod simply becomes another of the "multiple" earthing points along the run of the combined neutral and earth conductor. -- Cheers, John. /================================================== ===============\ | Internode Ltd - http://www.internode.co.uk | |-----------------------------------------------------------------| | John Rumm - john(at)internode(dot)co(dot)uk | \================================================= ================/ |
#5
Posted to uk.d-i-y
|
|||
|
|||
Thanks TN-C-S with additional earth rod
|