have a combi which gains pressure from 1 bar to 2-3 bar overnight and have
to release pressure. Suggestions so far include removing flexible loop ( is
this easy??) or leaking diverter valve (?). Any thoughts - it's a vokera.
Cheers


  #2   Report Post  
chris French
 
Posts: n/a
Default high combi pressure

In message , willsniffer
writes
have a combi which gains pressure from 1 bar to 2-3 bar overnight and have
to release pressure. Suggestions so far include removing flexible loop ( is
this easy??) or leaking diverter valve (?). Any thoughts - it's a vokera.


My first idea would be that there is a small flow of mains water into
the system gradually increasing pressure.

Techinically the filling loop is supposed to be disconnected anyway -
that's why you have one.

It's easy enough to remove, just undo one end of it. If it's is leaking
a bit of mains water into the system when shut then it will probably
still be leaking a bit when is connected to arrange something to collect
the water. If that is the problem you would need to replace the valve at
the mains end.
--
Chris French, Leeds
  #3   Report Post  
Christian McArdle
 
Posts: n/a
Default high combi pressure

have a combi which gains pressure from 1 bar to 2-3 bar overnight
and have to release pressure


It will probably one of two things.

1. A leaking (or partially open) tap on your filling loop. These must be
kept disconnected, but almost never are. If disconnecting it shows the tap
to be leaking slowly, it must be replaced. (It might just not be turned
off).

2. A leak in your heat exchanger. This allows mains water from the DHW side
to cross into the primary circulation water in the combi DHW heat exchanger
(or DHW cylinder as appropriate). This is more serious and expensive, but
MUST be fixed immediately.

Christian.


  #4   Report Post  
Ed Sirett
 
Posts: n/a
Default high combi pressure

willsniffer wrote:

have a combi which gains pressure from 1 bar to 2-3 bar overnight and have
to release pressure. Suggestions so far include removing flexible loop ( is
this easy??) or leaking diverter valve (?). Any thoughts - it's a vokera.
Cheers

See below.
--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is at www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
designing a central heating and hotwater system duncan UK diy 96 November 28th 05 02:32 PM
combi boiler pressure down - help please One Man Show UK diy 3 July 23rd 03 08:30 PM
Convert standard HW/CH system to Combi Bolier Charlie UK diy 5 July 10th 03 05:43 PM
New boiler IMM UK diy 25 July 6th 03 10:50 PM
Ariston euro combi problem BigWallop UK diy 0 July 4th 03 12:21 AM


All times are GMT +1. The time now is 02:20 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"