  #1   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 128
Default Replacing a central heating pump

I need to replace our ailing CH pump, a Grundfos UPS 15-50. The CH
system is a straightforward Y-plan set-up in a 4 bed house, with TRVs.

Grundfos literature recommends either their Alpha 2L 15-50 or UPS2
15-50/60 models.

Which is the better choice for performance, economy, reliability?
Any benefits/gotchas re installation[1] of one product versus the other?
Other brands worth considering?

[1] I'm aware of the horror stories re stuck isolation valves etc that
can afflict any pump replacement project :-(
  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,070
Default Replacing a central heating pump

On Tue, 09 Sep 2014 13:44:46 +0100, nemo
wrote:

I need to replace our ailing CH pump, a Grundfos UPS 15-50. The CH
system is a straightforward Y-plan set-up in a 4 bed house, with TRVs.

Grundfos literature recommends either their Alpha 2L 15-50 or UPS2
15-50/60 models.

Which is the better choice for performance, economy, reliability?
Any benefits/gotchas re installation[1] of one product versus the other?
Other brands worth considering?

[1] I'm aware of the horror stories re stuck isolation valves etc that
can afflict any pump replacement project :-(


When we had the CH installed just over 3 decades ago, the CH firm
fitted a Grundfos pump. Since this was our first experience with CH,
we just assumed that the low frequency vibration in the pipework was
'normal' (it wasn't exactly loud).

When it packed up 4 or 5 years later, I was rather put off fitting
another Grundfos and bodged a replacement from a similar sized
recirculation pump that my dad, bless him, had rescued from going into
the works skip (may have been part of the cooling system for the
innards of a water cooled IBM mainframe - he had a plum job of
maintaining the air conditioning plant at a major finance house).

These pumps were of the split dry electrical side / wet iron rotor
running in water lubed ceramic bearings, seperated by a thin aluminium
sheet. I only mention this in case anyone recognises the design as
being specific to a particulr brand or model range since I no longer
have them to hand to check for any maker's markings which, I'm now
unable to recall other than it most definitely wasn't a Grundfos pump.

Anyhoo, this type had the unfortunate habit of seizing up every other
year or thereabouts so it became a regular routine to swap out with
the other refurbed pump (my dad had managed to liberate another one of
these pumps). At first, the pump isolator valves 'worked as
advertised' but there did come a time, maybe 10 or 12 years later when
the isolator valves started to leak past the o ring seal on the
actuator spindle (screwdriver slotted ball valve type) and exhibited
leakage in the shut off position when I next had to fix the pump.

At this stage, I'd had enough of those 'cast offs' so, with some
reluctance I bought myself a replacement Grundfos UPS 15-60 130, along
with a pair of gate type isolator valves. After successfully
installing the new pump, I was staggered by the almost total absence
of vibration. The pump is still quietly beavering away over a decade
later, still just as quiet as the day I first powered it up.

I don't know why the first Grundfos pump had been less than silent,
and had finally failed after only 4 or 5 years of service, perhaps a
"Friday Afternoon" job in the factory or just possibly, the CH
installers had fitted a secondhand pump or maybe that second Grundfoss
was just an exceptionally well made example.

If my only experience with Grundfos had been just the replacement I
bought over a decade back, I'd have to say Grundfos can make a high
quality and reliable pump. My experience with the original rather
spoils things a little but I suppose I could assume that it was either
an exceptionally bad example or else had been a secondhand pump to
start with.

All I can say with any certainty about the Grundfos UPS 15-60 130
pump is that they can make a high quality pump. The only question is
whether they can do this consistently or only one in fifty times.

I think you'll need a consensus of opinion by a reasonable sample
size of DIYers or else the opinion of a CH engineer who's dealt with a
few hundred of these pumps in his time.

Incidentally, those other pumps I bodged up were about the same as
the original in terms of noise and vibration. This is why I was (and
remain) so impressed by that replacement Grundfos.

HTH &HAND
--
J B Good
  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 14,085
Default Replacing a central heating pump

On Wed, 10 Sep 2014 01:48:45 +0100, Johny B Good wrote:

I don't know why the first Grundfos pump had been less than silent,
and had finally failed after only 4 or 5 years of service, perhaps a
"Friday Afternoon" job in the factory or just possibly, the CH
installers had fitted a secondhand pump or ...


The stupid feckers didn't bleed it. None of the three pumps here were
bleed after the refurb. Two were reused from the old system so didn't
get much air out of them. The new one, in the solar thermal circuit,
was decidedly noisey until I bled it.

All three are quiet, though one mounted in some vertical pipe work
with a solid pipe clip where the pipe turns 90 deg to follow the
floor does transmit a bit of hum. I expect a thin bit of rubbery
stuff in the clip will stop that.

--
Cheers
Dave.



  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 128
Default Replacing a central heating pump

On 09/09/2014 13:44, nemo wrote:
I need to replace our ailing CH pump, a Grundfos UPS 15-50. The CH
system is a straightforward Y-plan set-up in a 4 bed house, with TRVs.

Grundfos literature recommends either their Alpha 2L 15-50 or UPS2
15-50/60 models.

Which is the better choice for performance, economy, reliability?
Any benefits/gotchas re installation[1] of one product versus the other?
Other brands worth considering?

[1] I'm aware of the horror stories re stuck isolation valves etc that
can afflict any pump replacement project :-(

Just found this document that compares the two models. Page 6 is
interesting, discussing the 'clever' features of the Alpha 2L. What does
the panel think?

http://assets.grahamplumbersmerchant.co.uk/product-docs/12276/12276.pdf
  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 66
Default Replacing a central heating pump

nemo wrote:
I need to replace our ailing CH pump, a Grundfos UPS 15-50. The CH
system is a straightforward Y-plan set-up in a 4 bed house, with TRVs.

Grundfos literature recommends either their Alpha 2L 15-50 or UPS2
15-50/60 models.

Which is the better choice for performance, economy, reliability?
Any benefits/gotchas re installation[1] of one product versus the other?
Other brands worth considering?

[1] I'm aware of the horror stories re stuck isolation valves etc that
can afflict any pump replacement project :-(


I had to strip ours down a few weeks ago, because a flake of magnetite
made it seize up. Easy fix, but having two sets of waterpump pliers is
handy. Big tray and old towels underneath, too. Our valves weren't
exactly stuck, but I couldn't stop them dripping copiously. Lots of
black sludge, too.


  #6   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 128
Default Replacing a central heating pump

On 09/09/2014 13:44, nemo wrote:
I need to replace our ailing CH pump, a Grundfos UPS 15-50. The CH
system is a straightforward Y-plan set-up in a 4 bed house, with TRVs.

Grundfos literature recommends either their Alpha 2L 15-50 or UPS2
15-50/60 models.

Which is the better choice for performance, economy, reliability?
Any benefits/gotchas re installation[1] of one product versus the other?
Other brands worth considering?

[1] I'm aware of the horror stories re stuck isolation valves etc that
can afflict any pump replacement project :-(


Update: I had a Grundfos Alpha 2L 15-50 pump fitted - I chickened out of
DIY and was glad I'd done so, given the struggle the plumber had with
removing the old one.

I was swayed to that model mainly by the promise of reduced noise
through the pump's electronics modulating pressure according to demand.
A secondary consideration was economy: between 5 and 24 W electrickery
consumed versus 7-48W for the alternative. The purchase price difference
of only about £5 helped as well. BTW the old one gobbled 70W on its
medium setting.

It has certainly delivered on the noise front - it's *very* quiet. We've
had to retrain ourselves not to worry that the heating isn't working
just because we can't hear the pump running.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
replacing a gas central heating boiler kent UK diy 11 May 15th 11 06:35 PM
Central heating controller - replacing Al Grant UK diy 1 June 18th 09 05:58 PM
Replacing a central heating clock Simon UK diy 8 November 10th 07 02:35 AM
Several things wrong with new flat - no central heating, low hot water pressure even with water pump, noisey pump kiich UK diy 69 July 13th 05 07:36 PM
Replacing Central Heating Timer Tony Lennard UK diy 3 January 15th 05 06:19 PM


All times are GMT +1. The time now is 09:06 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"