UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions.

 
 
LinkBack Thread Tools Search this Thread Display Modes
Prev Previous Post   Next Post Next
  #1   Report Post  
David C. Partridge
 
Posts: n/a
Default Replacement for old high output combi boiler

I'm looking to replace an ageing (1986 vintage) e.l.m. leblanc
GLM 5.32 combination boiler (conventional flue).

Both CH and DHW are 37.2kW (128000 btu/hr) net. DHW is fully
modulating, CH modulates to low as it reaches running temperature.

Amazingly for such an old boiler efficiency is quoted at 86%!

Flow rate is fine for a shower. Our large bath takes a long time to fill.
If a second tap is turned on it's a bit of a disaster (especially for the
person
under the shower).

I'm considering two options:

a) replacing it with a new combi with a HIGHER DHW output

b) going for system boiler with a heat store or sealed system hot water
tank.
However the DHW store or tank can ONLY go in the loft so pipe runs and
control wiring could get a bit tricky. I'm also concerned about the
economics
of keeping this hot 24/7 (we can't predict DHW use well enough to cope with
the "on twice" syndrome).

I'm currently leaning (strongly) to the first option, but I do realise that
the second
would give better DHW flow.

I've looked at some of the modern combis, but can't find any that can match
this
leblanc which does 16ltr/min for a 35K rise (though a few models from
Vaillant
seem to get close). I don't have the space to install two smaller ones,
and would
worry a lot about finding an engineer with the skills to do this right
anyway (I could
research it and DIM, but don't have the time or the Corgi certification).

Leblanc have withdrawn from UK and no longer make any high
output boilers anyway.

So what are the recommendations.

Thanks
Dave







 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
leaking heat exchanger in combi boiler (was:Vokera Linea 24 - heatexchanger ) Reestit Mutton UK diy 19 November 19th 03 12:55 PM
Calculating heat output for a replacement boiler bodger UK diy 7 November 11th 03 12:18 AM
Condensing boiler - odd installation mike.james UK diy 57 October 27th 03 08:19 PM
New Combi boiler GB UK diy 7 September 7th 03 11:34 PM
Combi Boiler / poor pressure brucej UK diy 12 August 21st 03 08:55 PM