#1
|
|||
|
|||
Baxi Bermuda 552
My 28 year old back boiler has just developed a water leak from the heat exchanger.
Can anybody help in advising if it is likely to be a simple gasket change or the exchanger itself. If it is the exchanger is it worth it based on the boilers age? The boiler has been very reliable since I fitted all those years ago. Many thanks Keith |
#2
Posted to uk.d-i-y
|
|||
|
|||
Baxi Bermuda 552
On 19/04/2013 21:45, Keith R wrote:
My 28 year old back boiler has just developed a water leak from the heat exchanger. Can anybody help in advising if it is likely to be a simple gasket change or the exchanger itself. If it is the exchanger is it worth it based on the boilers age? The boiler has been very reliable since I fitted all those years ago. Many thanks Keith Can you run it with the gas fire removed, and actually see where it's leaking? The heat exchanger is a fairly heavy cast iron affair, so I'd be surprised if it had rusted through. It's made of several bits bolted together, with gaskets in between - so a gasket failure is a likely candidate. Having said that, I wouldn't rate your chances of dismantling it non-destructively after 28 years. Nor, unfortunately, would I rate your chances of being able to buy a new one - unless you can find a good used one at a scrappy. -- Cheers, Roger ____________ Please reply to Newsgroup. Whilst email address is valid, it is seldom checked. |
#3
Posted to uk.d-i-y
|
|||
|
|||
Baxi Bermuda 552
On Apr 19, 9:45*pm, Keith R wrote:
My 28 year old back boiler has just developed a water leak from the heat exchanger. Can anybody help in advising if it is likely to be a simple gasket change or the exchanger itself. *If it is the exchanger is it worth it based on the boilers age? The boiler has been very reliable since I fitted all those years ago. Many thanks Keith -- Keith R It is junk because of it's age, inefficiency and it is self defeating because it draws (cold) combustion air into the room. Getting a new condensing, room sealed, wall hung boiler will likely cut gas bills by nearly 50% |
#4
Posted to uk.d-i-y
|
|||
|
|||
Baxi Bermuda 552
On 20/04/2013 08:59, harry wrote:
On Apr 19, 9:45 pm, Keith wrote: My 28 year old back boiler has just developed a water leak from the heat exchanger. Can anybody help in advising if it is likely to be a simple gasket change or the exchanger itself. If it is the exchanger is it worth it based on the boilers age? The boiler has been very reliable since I fitted all those years ago. Many thanks Keith -- Keith R It is junk because of it's age, inefficiency and it is self defeating because it draws (cold) combustion air into the room. Getting a new condensing, room sealed, wall hung boiler will likely cut gas bills by nearly 50% I'm surprised you know anything about boilers since, with all your solar panels, you presumably have no need of such crude devices! To the OP: If you can't easily find and cure the leak, it may well be time to consider replacing the boiler. If you like the Bermudu concept, there is now a condensing version which (apparently) meets the latest efficiency requirements. -- Cheers, Roger ____________ Please reply to Newsgroup. Whilst email address is valid, it is seldom checked. |
#5
Posted to uk.d-i-y
|
|||
|
|||
Baxi Bermuda 552
On Apr 20, 10:15*am, Roger Mills wrote:
On 20/04/2013 08:59, harry wrote: On Apr 19, 9:45 pm, Keith *wrote: My 28 year old back boiler has just developed a water leak from the heat exchanger. Can anybody help in advising if it is likely to be a simple gasket change or the exchanger itself. *If it is the exchanger is it worth it based on the boilers age? The boiler has been very reliable since I fitted all those years ago. Many thanks Keith -- Keith R It is junk because of it's age, inefficiency and it is self defeating because it draws (cold) combustion air into the room. Getting a new condensing, room sealed, wall hung boiler will likely cut gas bills by nearly 50% I'm surprised you know anything about boilers since, with all your solar panels, you presumably have no need of such crude devices! I have no need for central heating now as I have a solar passive house. But in days gone by I had a CORGI certificate because of the gas fitters I had working for me. Mostly but not entirely industrial boilers. |
#6
Posted to uk.d-i-y
|
|||
|
|||
Baxi Bermuda 552
On Sat, 20 Apr 2013 00:59:02 -0700 (PDT), harry wrote:
It is junk because of it's age, inefficiency and it is self defeating because it draws (cold) combustion air into the room. Getting a new condensing, room sealed, wall hung boiler will likely cut gas bills by nearly 50% Just looked it up in the SEBUK database http://www.boilers.org.uk/ (I would post a direct link but they hide those). Gawd is that a crap boiler SAP 2009 Annual effciency of 65%... A decent condensing modern boiler will certainly cut the gas bill noticeably. Installing a modern boiler might be more fun as that Baxi is a back boiler and modern boilers tend to require being mounted on an external wall. I don't know if you can get a condensing back boiler, that will be happy with presumably a normal height flue attached, even fitting the condensate drain might be fun... As a stop gap I wonder of some rad weld added to the primary would stop the leak whilst the research/planning for the replacement is carried out. -- Cheers Dave. |
Reply |