Duel Heat Towel Rail install
HI
I have installed a duel fuel heated towel rail in the bathroom. Works great on CH.. (combi boiler) now need to wire it for summer use !! Need advice; Electric cable from radiator goes through wall to cupboard which used to have ho****er tank in it, and therefore wall plug that used to be used for immersion heating element. I want to put a Digital timer in there... am I correct .... electric plug to timer..timer to radiator ? is this OK ? ( i believe the heating element in these radiators have there own theomstat.) Next; do I close off the values on the radiator in the summer ... have 2 installed (on in and out).... so the heated water does not travel out of the radiator and round the system . An advice ..pointers... or to say all is OK in my set up would be great. Thank you in advance... R |
#2
Posted to uk.d-i-y
|
|||
|
|||
Duel Heat Towel Rail install
ramrod wrote:
HI I have installed a duel fuel heated towel rail in the bathroom. Works great on CH.. (combi boiler) now need to wire it for summer use !! Need advice; Electric cable from radiator goes through wall to cupboard which used to have ho****er tank in it, and therefore wall plug that used to be used for immersion heating element. I want to put a Digital timer in there... am I correct .... electric plug to timer..timer to radiator ? is this OK ? ( i believe the heating element in these radiators have there own theomstat.) RCD protected I hope. Next; do I close off the values on the radiator in the summer ... have 2 installed (on in and out).... so the heated water does not travel out of the radiator and round the system . My parents never close a valve off and they have no problems, however they have the pipework rising to the rads, it might be different if the pipework ran down to the rads. -- Adam |
#3
Posted to uk.d-i-y
|
|||
|
|||
Duel Heat Towel Rail install
"ramrod" wrote in message ... HI I have installed a duel fuel heated towel rail in the bathroom. Works great on CH.. (combi boiler) now need to wire it for summer use !! Need advice; Electric cable from radiator goes through wall to cupboard which used to have ho****er tank in it, and therefore wall plug that used to be used for immersion heating element. I want to put a Digital timer in there... am I correct .... electric plug to timer..timer to radiator ? is this OK ? ( i believe the heating element in these radiators have there own theomstat.) Next; do I close off the values on the radiator in the summer ... have 2 installed (on in and out).... so the heated water does not travel out of the radiator and round the system . An advice ..pointers... or to say all is OK in my set up would be great. Thank you in advance... R I would be worried about having no pressure relief if the valves are closed. I would leave one open half a turn. Baz |
#4
Posted to uk.d-i-y
|
|||
|
|||
Duel Heat Towel Rail install
On Wed, 6 Apr 2011 14:52:42 +0100, "Baz"
wrote: "ramrod" wrote in message ... HI I have installed a duel fuel heated towel rail in the bathroom. Works great on CH.. (combi boiler) now need to wire it for summer use !! Need advice; Electric cable from radiator goes through wall to cupboard which used to have ho****er tank in it, and therefore wall plug that used to be used for immersion heating element. I want to put a Digital timer in there... am I correct .... electric plug to timer..timer to radiator ? is this OK ? ( i believe the heating element in these radiators have there own theomstat.) Next; do I close off the values on the radiator in the summer ... have 2 installed (on in and out).... so the heated water does not travel out of the radiator and round the system . An advice ..pointers... or to say all is OK in my set up would be great. Thank you in advance... R I would be worried about having no pressure relief if the valves are closed. I would leave one open half a turn. The towel rails that are electric-only - i.e the oil-filled ones - have expansion space within, so it's obviously a consideration (although the expansion rates of the two liquids will, I expect, differ quite a bit). |
#5
Posted to uk.d-i-y
|
|||
|
|||
Duel Heat Towel Rail install
"Appelation Controlee" wrote in message ... On Wed, 6 Apr 2011 14:52:42 +0100, "Baz" wrote: "ramrod" wrote in message ... HI I have installed a duel fuel heated towel rail in the bathroom. Works great on CH.. (combi boiler) now need to wire it for summer use !! Need advice; Electric cable from radiator goes through wall to cupboard which used to have ho****er tank in it, and therefore wall plug that used to be used for immersion heating element. I want to put a Digital timer in there... am I correct .... electric plug to timer..timer to radiator ? is this OK ? ( i believe the heating element in these radiators have there own theomstat.) Next; do I close off the values on the radiator in the summer ... have 2 installed (on in and out).... so the heated water does not travel out of the radiator and round the system . An advice ..pointers... or to say all is OK in my set up would be great. Thank you in advance... R I would be worried about having no pressure relief if the valves are closed. I would leave one open half a turn. The towel rails that are electric-only - i.e the oil-filled ones - have expansion space within, so it's obviously a consideration (although the expansion rates of the two liquids will, I expect, differ quite a bit). It is the possible steam pressure, if the stat fails, that would worry me. Baz |
#6
Posted to uk.d-i-y
|
|||
|
|||
Duel Heat Towel Rail install
On Wed, 6 Apr 2011 16:58:20 +0100, "Baz"
wrote: "Appelation Controlee" wrote in message .. . On Wed, 6 Apr 2011 14:52:42 +0100, "Baz" wrote: "ramrod" wrote in message ... HI I have installed a duel fuel heated towel rail in the bathroom. Works great on CH.. (combi boiler) now need to wire it for summer use !! Need advice; Electric cable from radiator goes through wall to cupboard which used to have ho****er tank in it, and therefore wall plug that used to be used for immersion heating element. I want to put a Digital timer in there... am I correct .... electric plug to timer..timer to radiator ? is this OK ? ( i believe the heating element in these radiators have there own theomstat.) Next; do I close off the values on the radiator in the summer ... have 2 installed (on in and out).... so the heated water does not travel out of the radiator and round the system . An advice ..pointers... or to say all is OK in my set up would be great. Thank you in advance... R I would be worried about having no pressure relief if the valves are closed. I would leave one open half a turn. The towel rails that are electric-only - i.e the oil-filled ones - have expansion space within, so it's obviously a consideration (although the expansion rates of the two liquids will, I expect, differ quite a bit). It is the possible steam pressure, if the stat fails, that would worry me. The towel rail (elec. only) that we have is only 80 watts. Not sure it even has a stat (although there may be a thermal cut-out). It takes quite some time to warm up. |
#7
Posted to uk.d-i-y
|
|||
|
|||
Duel Heat Towel Rail install
On Apr 7, 10:06*am, Appelation Controlee wrote:
On Wed, 6 Apr 2011 16:58:20 +0100, "Baz" wrote: "Appelation Controlee" wrote in message .. . On Wed, 6 Apr 2011 14:52:42 +0100, "Baz" wrote: "ramrod" wrote in message .... HI I have installed a duel fuel heatedtowelrail in the bathroom. *Works great on CH.. (combi boiler) now need to wire it for summer use !! Need advice; Electric cable from radiator goes through wall to cupboard which used to have ho****er tank in it, and therefore wall plug that used to be used for *immersion heating element. I want to put a Digital timer in there... am I correct .... electric plug to timer..timer to radiator ? *is this OK ? *( i believe the heating element in these radiators have there own theomstat.) Next; *do I close off the values on the radiator in the summer * ... have 2 installed (on in and out).... so the heated water does not travel out of the radiator and round the system . An advice ..pointers... or to say all is OK in my set up would be great. Thank you in advance... R I would be worried about having no pressure relief if the valves are closed. I would leave one open half a turn. Thetowelrails that are electric-only - i.e the oil-filled ones - have expansion space within, so it's obviously a consideration (although the expansion rates of the two liquids will, I expect, differ quite a bit). It is the possible steam pressure, if the stat fails, that would worry me. Thetowelrail (elec. only) that we have is only 80 watts. Not sure it even has a stat (although there may be a thermal cut-out). It takes quite some time to warm up.- Hide quoted text - - Show quoted text - Thanks for your advice... will put rcd on plug for towel rail .... Also will leave value open on towel rad ... in heat leave area to pipe work will close one valve... Thanks guys ! |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Towel Rail Hell | UK diy | |||
Towel Rail Qestion | UK diy | |||
Towel rail too big? | UK diy | |||
Who Makes Duel Fuel Heat Pumps - Single Package | Home Ownership |