Default Cable from damp shed

Hi.
Just taken a reel of 2.5mm cable from shed.
The cardboard 'wheel' is damp. Is the cable safe to use?

Thanks.

Arthur


  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3,703
Default Cable from damp shed

In article , Arthur51
writes
Hi.
Just taken a reel of 2.5mm cable from shed.
The cardboard 'wheel' is damp. Is the cable safe to use?

The ends are the only issue and it's unlikely that the damp has
penetrated far. Strip the free end to see if there is any discolouration
and discard any that isn't clean but I would expect it to be fine.
--
fred
FIVE TV's superbright logo - not the DOG's, it's ********
  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,683
Default Cable from damp shed

On Mar 31, 3:47*pm, "Arthur51" wrote:
Just taken a reel of 2.5mm cable from shed.
The cardboard 'wheel' is damp. *Is the cable safe to use?


Consider how damp the local unheated electrical factors warehouse is.

The cardboard is damp because the large body of copper between it has
a temperature below the dew point of the shed environment, thus
condensation will naturally form on cable sheath, metal tube & even
cardboard surfaces. The same environment exists in an unheated
electrical factors warehouse - perhaps worse re human bodies wandering
about dumping moisture into the air and not perfectly sealing roller
shutters.

If concerned cut off the first 1m (10cm will probably suffice).


It is SWA that you need to be most concerned about, because the armour
is c.90% coverage - 10% air voids do allow water to be drawn up by
capillary action & limited thermal cycling. The air voids also allow
water to track down in an enclosure past a bottom fitted CW gland and
around the armour cable which has been cut - hence the twist-below-the-
gland-crunch-test for rotten armour on sites. E1W or CCG glands avoid
this problem by sealing against the bedding and not just the outer
sheath, they cost a bit more though.
  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 39,563
Default Cable from damp shed

Arthur51 wrote:
Hi.
Just taken a reel of 2.5mm cable from shed.
The cardboard 'wheel' is damp. Is the cable safe to use?

yes.

Thanks.

Arthur


  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 209
Default Cable from damp shed

On 31 Mar, 15:47, "Arthur51" wrote:
Hi.
Just taken a reel of 2.5mm cable from shed.
The cardboard 'wheel' is damp. *Is the cable safe to use?

Thanks.

Arthur


Perfectly so.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Armoured Cable for Shed mark UK diy 49 December 16th 09 08:00 PM
Damp spots, wall already injection treated for rising damp ppmoore UK diy 3 August 22nd 09 09:59 PM
Shed bases, damp, and condensation Pete Verdon UK diy 6 December 14th 07 12:36 PM
Damp proof membrane for shed wall John UK diy 4 September 26th 06 04:44 PM
Damp treatment for *severe* penetrating damp [email protected] UK diy 17 April 6th 06 12:28 PM


All times are GMT +1. The time now is 05:09 AM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"