[email protected] October 20th 08 02:52 PM

RCBOs - the wiggly blue madness!
 
If you were to fill a large consumer unit with RCBOs, it looks to me
like you'd have trouble fitting all the wires in, let alone connect
the final circuits. Is there a knack to dealing with all the wiggly
blue wires, or a best practice? Alternatively is there a make of CU
that has more room inside?

T

Tim S October 20th 08 02:59 PM

RCBOs - the wiggly blue madness!
 
coughed up some electrons that declared:

If you were to fill a large consumer unit with RCBOs, it looks to me
like you'd have trouble fitting all the wires in, let alone connect
the final circuits. Is there a knack to dealing with all the wiggly
blue wires, or a best practice? Alternatively is there a make of CU
that has more room inside?

T


I'm in the process of ordering a Hager industrial Type A metal board (like
this:

http://www.sparksdirect.co.uk/hager-...d-p-14028.html

But the 20way version
)

It claims to be roomy. It's not an ugly board, but it's not very subtle
either - mine's getting a wiring cupboard built around it anyway.

I'll have mine in a couple of weeks - I can take photos if you can wait that
long.

Cheers

Tim

Andrew Gabriel October 20th 08 04:25 PM

RCBOs - the wiggly blue madness!
 
In article ,
writes:
If you were to fill a large consumer unit with RCBOs, it looks to me
like you'd have trouble fitting all the wires in, let alone connect
the final circuits. Is there a knack to dealing with all the wiggly
blue wires, or a best practice? Alternatively is there a make of CU
that has more room inside?


I used MEM (now Eaton) Memshield2...

http://www.cucumber.demon.co.uk/cu1.jpg
http://www.cucumber.demon.co.uk/cu2.jpg

Bags of space inside. Very nice consumer units to work with.
Probably not cheap compared with domestic consumer units.

--
Andrew Gabriel
[email address is not usable -- followup in the newsgroup]

Micky Savage[_2_] October 20th 08 05:19 PM

RCBOs - the wiggly blue madness!
 

"Andrew Gabriel" wrote in message
...
In article
,
writes:
If you were to fill a large consumer unit with RCBOs, it looks to me
like you'd have trouble fitting all the wires in, let alone connect
the final circuits. Is there a knack to dealing with all the wiggly
blue wires, or a best practice? Alternatively is there a make of CU
that has more room inside?


I used MEM (now Eaton) Memshield2...

http://www.cucumber.demon.co.uk/cu1.jpg
http://www.cucumber.demon.co.uk/cu2.jpg

Bags of space inside. Very nice consumer units to work with.
Probably not cheap compared with domestic consumer units.

--
Andrew Gabriel
[email address is not usable -- followup in the newsgroup]





Hi All,


welcome to electrics,




micky



neverwas[_3_] October 20th 08 05:47 PM

RCBOs - the wiggly blue madness!
 

I used MEM (now Eaton) Memshield2...

http://www.cucumber.demon.co.uk/cu1.jpg
http://www.cucumber.demon.co.uk/cu2.jpg

Bags of space inside. Very nice consumer units to work with.
Probably not cheap compared with domestic consumer units.


I liked the way that example had a box before the CU which reduced the
number of wires in the CU. Wd that be OK in a domestic installation so
long as there is (as in your example) no gap between the 2 boxes (and of
course the singles are rated to cope)?
--
Robin



Andrew Gabriel October 20th 08 06:16 PM

RCBOs - the wiggly blue madness!
 
In article ,
"neverwas" writes:

I used MEM (now Eaton) Memshield2...

http://www.cucumber.demon.co.uk/cu1.jpg
http://www.cucumber.demon.co.uk/cu2.jpg

Bags of space inside. Very nice consumer units to work with.
Probably not cheap compared with domestic consumer units.


I liked the way that example had a box before the CU which reduced the
number of wires in the CU. Wd that be OK in a domestic installation so
long as there is (as in your example) no gap between the 2 boxes (and of
course the singles are rated to cope)?


That's simply because the wires weren't long enough after
swapping the CU. I wouldn't do that if starting from scratch,
although it's fine from the regulatory point of view.

--
Andrew Gabriel
[email address is not usable -- followup in the newsgroup]

neverwas[_3_] October 20th 08 11:37 PM

RCBOs - the wiggly blue madness!
 
That's simply because the wires weren't long enough after
swapping the CU. I wouldn't do that if starting from scratch,
although it's fine from the regulatory point of view.


Thanks. I asked as I've faced just that situation; and what you had
done seemed to me much neater and more flexible than crimping on bits of
cable.
--
Robin