TheScullster February 29th 08 12:28 PM

Bell Box Operation
 
Hi all

Just received my alarm parts ready for upgrade.
One question that came to mind relates to the bell box.
If the backup battery is removed/disconnected from the bell, will the bell
still work off the panel power?
Is the backup battery only used in the event of power being cut between the
panel and the bell?

TIA

Phil



George February 29th 08 12:41 PM

Bell Box Operation
 

"TheScullster" wrote in message
. uk...
Hi all

Just received my alarm parts ready for upgrade.
One question that came to mind relates to the bell box.
If the backup battery is removed/disconnected from the bell, will the bell
still work off the panel power?
Is the backup battery only used in the event of power being cut between

the
panel and the bell?

TIA

Phil



See SAB & SCB

http://www.diy-alarms.co.uk/catalog/glossary.php



fred February 29th 08 01:55 PM

Bell Box Operation
 
In article ,
TheScullster writes
Hi all

Just received my alarm parts ready for upgrade.
One question that came to mind relates to the bell box.
If the backup battery is removed/disconnected from the bell, will the bell
still work off the panel power?
Is the backup battery only used in the event of power being cut between the
panel and the bell?

Yes, provided you have connections to + (aka + holdoff), - (aka -
holdoff) and trigger (aka just about anything). Wouldn't do it myself
for extended operation though.
--
fred
Plusnet - I hope you like vanilla

davy12342 March 9th 08 12:05 AM

Bell Box Operation
 
Take a look at www.ukpanels.com
If you get problems there are engineers online