DIYbanter

DIYbanter (https://www.diybanter.com/)
-   UK diy (https://www.diybanter.com/uk-diy/)
-   -   Slow HW, slow rads, boiler clunking... (https://www.diybanter.com/uk-diy/228193-slow-hw-slow-rads-boiler-clunking.html)

[email protected] January 1st 08 09:54 PM

Slow HW, slow rads, boiler clunking...
 

These problems may not be related...

I have a Worcester Bosch Greenstar boiler (an early condensing combi)
about 6 years old. For some months the hot water has taking about 3-4
minutes to come out hot, as if the pre-heated store isn't working.
Timeswitch is set correctly, the boiler is not in ECO mode.

Also, in the last week the rads have been taking a long time to get
warm. The rads upstairs get hot first while the downstairs ones are
still cold. The burner comes on for about 3 minutes or so then off for
3 minutes, so the whole house is taking hours to heat up. There is a
clunking noise coming from somewhere inside the boiler.

Any ideas? Pump? Sludge in the pipes - the central heating system is
also 6 years old. Whihc should I check first?

Many thanks!

Harry Bloomfield[_2_] January 1st 08 11:03 PM

Slow HW, slow rads, boiler clunking...
 

wrote in message
...

These problems may not be related...

I have a Worcester Bosch Greenstar boiler (an early condensing combi)
about 6 years old. For some months the hot water has taking about 3-4
minutes to come out hot, as if the pre-heated store isn't working.
Timeswitch is set correctly, the boiler is not in ECO mode.

Also, in the last week the rads have been taking a long time to get
warm. The rads upstairs get hot first while the downstairs ones are
still cold. The burner comes on for about 3 minutes or so then off for
3 minutes, so the whole house is taking hours to heat up. There is a
clunking noise coming from somewhere inside the boiler.

Any ideas? Pump? Sludge in the pipes - the central heating system is
also 6 years old. Whihc should I check first?

Many thanks!


Check the pump is rotating - Remove the silver screw ( expect some water
leaking out) and see if the shaft end is rotating.



John Rumm January 2nd 08 03:42 AM

Slow HW, slow rads, boiler clunking...
 
wrote:

Any ideas? Pump? Sludge in the pipes - the central heating system is
also 6 years old. Whihc should I check first?


Sounds like a pump problem or other obstruction in the primary water flow.

--
Cheers,

John.

/================================================== ===============\
| Internode Ltd -
http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/

Ed Sirett January 2nd 08 08:23 PM

Slow HW, slow rads, boiler clunking...
 
On Tue, 01 Jan 2008 13:54:36 -0800, jpcoetzee wrote:

These problems may not be related...

I have a Worcester Bosch Greenstar boiler (an early condensing combi)
about 6 years old. For some months the hot water has taking about 3-4
minutes to come out hot, as if the pre-heated store isn't working.
Timeswitch is set correctly, the boiler is not in ECO mode.

Also, in the last week the rads have been taking a long time to get
warm. The rads upstairs get hot first while the downstairs ones are
still cold. The burner comes on for about 3 minutes or so then off for 3
minutes, so the whole house is taking hours to heat up. There is a
clunking noise coming from somewhere inside the boiler.

Any ideas? Pump? Sludge in the pipes - the central heating system is
also 6 years old. Whihc should I check first?

Many thanks!


I would say you probably have some flow but not enough. I'd suspect a
partially detached impeller in the pump. Sludge is possibly involved but
as the symptoms came on suddenly I suspect the pump.

It is often possible to change the pump head as they are often big
standard grundfoss units, held by 4 allen bolts and a big o-ring.



--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is at http://www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html
Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html


Scrump January 8th 08 09:48 AM

Slow HW, slow rads, boiler clunking...
 
Many thanks to all - it was indeed the pump.


All times are GMT +1. The time now is 09:51 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004 - 2014 DIYbanter