On Sat, 07 Jul 2007 05:30:35 -0700, cynic wrote:
On 7 Jul, 12:30, wrote: Hi, I'm helping a friend out who is in hospital with his wife who is in labour! Basically the pilot light on their SIME combi boiler won't stay lit and the pressure on the boiler is 3.25 bar when cold. It's a saturday so not a good day for this to happen (especially as they'll be arriving home with their first child shortly!) Plumbers are asking £70+ just to look at it but i have a feeling they will then say they need a part and that the wholesalers are shut till monday, so my questions are as follows: a) any ideas on a quick fix for this? (For someone who doesn't know much about boilers..i doubt it somehow) b) Is a plumber likely to need parts? If yes,then I guess it's better not to even get them out till monday and avoid extra call out charges what do you think? Thanks! Charlie Firstly - the pilot light may not be a permanently lit one! You didn't quote a model. He did, it's a [Vaillant] Sime and it has a permanent pilot. Secondly the pressure "should" be venting out of the safety valve at 3 bar (unless the gauge is telling lies) is the pipe discharging water outside? Separate but unhelpful problem. The discharge valve should have operated at this level, perhaps it is and the fill loop is letting by. See SealedCH FAQ. £70 sounds perfectly reasonable for a call out. Yes - parts may be required unless you have fortunately chanced upon a guy with decent van stock The boiler is somewhat old. It's the thermocouple £15 [1] or it's over heating. The latter could be the end of the boiler (let's say the heat exchanger is blocked by debris due to the perpetual filling?). HTH [1] Yes it's includes connections to the O/H stat so not a generic part. -- Ed Sirett - Property maintainer and registered gas fitter. The FAQ for uk.diy is at http://www.diyfaq.org.uk Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html Gas Fitting Standards Docs he http://www.makewrite.demon.co.uk/GasFittingStandards |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Pilot Light on Ideal W2000 boiler | UK diy | |||
Boiler pilot light gasp ressure low | UK diy | |||
Vaillant combi boiler - pilot light keeps going out | UK diy | |||
Pilot light out and vibrations on a Potterton Puma 80 combi | UK diy | |||
Boiler pilot light went out | UK diy |