Default Compression fittings on chrome pipe

Hi All

I am debating the best type of connection for joining tap connectors
to 22mm chrome plated copper pipe.
My plumbing skills are adequate but not exactly neat so I am unsure
whether to use solder ring or compression fittings?
I would have to file off the chrome for soldering and there's a very
good chance the extra solder i put on (copying my plumber mate there)
would surely run down the nice shiny chrome pipe and spoil it.
Compression would be neater but the fittings are bulkier, also i'm not
sure how the olives will grip on the chromed surface.

Any tips or pointers Gents?

  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 464
Default Compression fittings on chrome pipe


"Fred" wrote in message
...

"Brian Sharrock" wrote in message
...

"Dave Fawthrop" wrote in message
...
On 2 Apr 2007 08:59:06 -0700, wrote:

|!Hi All
|!
|!I am debating the best type of connection for joining tap connectors
|!to 22mm chrome plated copper pipe.
|!My plumbing skills are adequate but not exactly neat so I am unsure
|!whether to use solder ring or compression fittings?
|!I would have to file off the chrome for soldering and there's a very
|!good chance the extra solder i put on (copying my plumber mate there)
|!would surely run down the nice shiny chrome pipe and spoil it.
|!Compression would be neater but the fittings are bulkier, also i'm not
|!sure how the olives will grip on the chromed surface.

Are you sure that the pipe is chrome plated copper? scratch it and see!
I have used stainless steel pipe with compression fittings, no problems.
--
Dave Fawthrop sf hyphenologist.co.uk


I have used 15mm chromed copper pipes with compression fittings - just
sandpaper off the chrome to reveal copper below.


Why? Won't the olive cut through the chrome and create a good seal
without removing any chrome?

Why? Experience!

I tried to make a 'conventional' compression joint onto a chromed pipe - and
fundamentally; it pulled off when pressurised. I twiddled one of the
cylinder pipe cleaners thingy around it - abrading off the shiny chrome -
and reconnected - voila -watertight; no drips.
Without going into the metallurgy - I suspect that chrome is harder than the
brass 'olive.

I've only got two such joints in the house - a chrome downpipe-feed into the
toilet's cistern.
[The toilet cistern's connection cum service valve is chrome and I opined
that a Cu feed pipe would look naff] ... however next time I'll channel the
(rear) wall and not have any supply pipe visible. with the service valve
inside the cistern. It's astonishing how 'tunnel vision' overcomes one
when the 'bog' is out-of-service for even a short time.

--

Brian





  #6   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 278
Default Compression fittings on chrome pipe

On Apr 2, 4:59 pm, wrote:
Hi All

I am debating the best type of connection for joining tap connectors
to 22mm chrome plated copper pipe.
My plumbing skills are adequate but not exactly neat so I am unsure
whether to use solder ring or compression fittings?
I would have to file off the chrome for soldering and there's a very
good chance the extra solder i put on (copying my plumber mate there)
would surely run down the nice shiny chrome pipe and spoil it.
Compression would be neater but the fittings are bulkier, also i'm not
sure how the olives will grip on the chromed surface.

Any tips or pointers Gents?


Hi

I can't say whether it is right or wrong but I've used these...

http://www.screwfix.com/app/sfd/cat/...8014&ts=47080#

.... on all my radiators and the taps in the bathroom. They are chrome
plated copper and none of them leaked when using conventional
compression fittings.

Steve

  #7   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 50
Default Compression fittings on chrome pipe


"Brian Sharrock" wrote in message
...
I tried to make a 'conventional' compression joint onto a chromed pipe -
and fundamentally; it pulled off when pressurised. I twiddled one of the
cylinder pipe cleaners thingy around it - abrading off the shiny chrome -
and reconnected - voila -watertight; no drips.
Without going into the metallurgy - I suspect that chrome is harder than
the brass 'olive.


Are olives supposed work by cutting into the pipe to a small extent?
The question for me with stainless pipe was brass or copper olives.
I tried brass first but drips could not be stopped. 2nd with copper olives
was ok.

As copper olives are much softer than the stainless, the copper olive must
be deforming to take up any imperfections in the pipe - but is there as
possibility it might blow off later as it can't have cut into the stainless?

Are there any special olives for stainless pipe?

Roger R


  #9   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 4,410
Default Compression fittings on chrome pipe


wrote in message
oups.com...
Hi All

I am debating the best type of connection for joining tap connectors
to 22mm chrome plated copper pipe.
My plumbing skills are adequate but not exactly neat so I am unsure
whether to use solder ring or compression fittings?
I would have to file off the chrome for soldering and there's a very
good chance the extra solder i put on (copying my plumber mate there)
would surely run down the nice shiny chrome pipe and spoil it.


Wipe the excess off with a cloth while it is still hot. Assuming you use a
water approved flux, the excess will not bond to the chrome.

Compression would be neater but the fittings are bulkier, also i'm not
sure how the olives will grip on the chromed surface.

Any tips or pointers Gents?


You should take the chrome off for any type of fitting. Heating the end of
the pipe and dipping it in hydrochloric acid is my preferred method, but not
one I would recommend for the inexperienced.

Colin Bignell


  #11   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 25
Default Compression fittings on chrome pipe

Thanks All for your insight

The pipe is copper and I have have successfully soldered the other end
of the pipe that is going under the floorboards without leaks under
mains pressure (by taking the chrome off first)
Think I'll be taking the compression route and taking off the chrome
plating where the olive will be sited. Do I need to be careful not to
overtighten on compressions?

  #12   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 4,410
Default Compression fittings on chrome pipe


wrote in message
ups.com...
Thanks All for your insight

The pipe is copper and I have have successfully soldered the other end
of the pipe that is going under the floorboards without leaks under
mains pressure (by taking the chrome off first)
Think I'll be taking the compression route and taking off the chrome
plating where the olive will be sited. Do I need to be careful not to
overtighten on compressions?


Hand tight plus half a turn is the traditional advice, but I find that
people have different values for hand tight.

Colin Bignell


  #13   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,158
Default Compression fittings on chrome pipe


"nightjar .uk.com" nightjar@insert my surname here wrote in
message ...

wrote in message
ups.com...
Thanks All for your insight

The pipe is copper and I have have successfully soldered the other

end
of the pipe that is going under the floorboards without leaks

under
mains pressure (by taking the chrome off first)
Think I'll be taking the compression route and taking off the

chrome
plating where the olive will be sited. Do I need to be careful not

to
overtighten on compressions?


Hand tight plus half a turn is the traditional advice, but I find

that
people have different values for hand tight.

Colin Bignell



IIUI there is absolutely no need to remove the chrome plating under
the olive, the olive will crush seal onto the chrome quite
satisfactorily

AWEM


  #14   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 25
Default Compression fittings on chrome pipe

My next challenge seems to be sourcing the fitting I need!

Does this fitting exist?:

22mm to 3/4 bent tap connector (compression)

Ringing round I can't find one anywhere??

  #15   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,158
Default Compression fittings on chrome pipe


wrote in message
ups.com...
My next challenge seems to be sourcing the fitting I need!

Does this fitting exist?:

22mm to 3/4 bent tap connector (compression)

Ringing round I can't find one anywhere??


Try BES part number 7417

http://www.bes.ltd.uk/

AWEM




  #16   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,982
Default Compression fittings on chrome pipe

On Mon, 02 Apr 2007 08:59:06 -0700, oldskoolskater wrote:

Any tips or pointers Gents?


Compression with brass olives.

(just my 0.02 euros'orth :-))
  #17   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 77
Default Compression fittings on chrome pipe


"Brian Sharrock" wrote in message
...

"Fred" wrote in message
...

"Brian Sharrock" wrote in message
...

"Dave Fawthrop" wrote in message
...
On 2 Apr 2007 08:59:06 -0700, wrote:

|!Hi All
|!
|!I am debating the best type of connection for joining tap connectors
|!to 22mm chrome plated copper pipe.
|!My plumbing skills are adequate but not exactly neat so I am unsure
|!whether to use solder ring or compression fittings?
|!I would have to file off the chrome for soldering and there's a very
|!good chance the extra solder i put on (copying my plumber mate there)
|!would surely run down the nice shiny chrome pipe and spoil it.
|!Compression would be neater but the fittings are bulkier, also i'm
not
|!sure how the olives will grip on the chromed surface.

Are you sure that the pipe is chrome plated copper? scratch it and see!
I have used stainless steel pipe with compression fittings, no
problems.
--
Dave Fawthrop sf hyphenologist.co.uk

I have used 15mm chromed copper pipes with compression fittings - just
sandpaper off the chrome to reveal copper below.


Why? Won't the olive cut through the chrome and create a good seal
without removing any chrome?

Why? Experience!

I tried to make a 'conventional' compression joint onto a chromed pipe -
and fundamentally; it pulled off when pressurised. I twiddled one of the
cylinder pipe cleaners thingy around it - abrading off the shiny chrome -
and reconnected - voila -watertight; no drips.
Without going into the metallurgy - I suspect that chrome is harder than
the brass 'olive.

I've only got two such joints in the house - a chrome downpipe-feed into
the toilet's cistern.
[The toilet cistern's connection cum service valve is chrome and I opined
that a Cu feed pipe would look naff] ... however next time I'll channel
the (rear) wall and not have any supply pipe visible. with the service
valve inside the cistern. It's astonishing how 'tunnel vision'
overcomes one when the 'bog' is out-of-service for even a short time.


I'm rather surprised. Olives bind onto copper pipe through shrinkage and a
thin layer of chrome shouldn't have any effect. If there's any doubt I
would give the fitting another 1/2 turn to ensure the olive shrinks down and
binds onto the pipe.


  #18   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 464
Default Compression fittings on chrome pipe


"Fred" wrote in message
...

"Brian Sharrock" wrote in message
...

"Fred" wrote in message
...

"Brian Sharrock" wrote in message
...

"Dave Fawthrop" wrote in message
...
On 2 Apr 2007 08:59:06 -0700, wrote:

|!Hi All
|!
|!I am debating the best type of connection for joining tap connectors
|!to 22mm chrome plated copper pipe.
|!My plumbing skills are adequate but not exactly neat so I am unsure
|!whether to use solder ring or compression fittings?
|!I would have to file off the chrome for soldering and there's a very
|!good chance the extra solder i put on (copying my plumber mate
there)
|!would surely run down the nice shiny chrome pipe and spoil it.
|!Compression would be neater but the fittings are bulkier, also i'm
not
|!sure how the olives will grip on the chromed surface.

Are you sure that the pipe is chrome plated copper? scratch it and
see!
I have used stainless steel pipe with compression fittings, no
problems.
--
Dave Fawthrop sf hyphenologist.co.uk

I have used 15mm chromed copper pipes with compression fittings - just
sandpaper off the chrome to reveal copper below.


Why? Won't the olive cut through the chrome and create a good seal
without removing any chrome?

Why? Experience!

I tried to make a 'conventional' compression joint onto a chromed pipe -
and fundamentally; it pulled off when pressurised. I twiddled one of the
cylinder pipe cleaners thingy around it - abrading off the shiny chrome -
and reconnected - voila -watertight; no drips.
Without going into the metallurgy - I suspect that chrome is harder than
the brass 'olive.

I've only got two such joints in the house - a chrome downpipe-feed into
the toilet's cistern.
[The toilet cistern's connection cum service valve is chrome and I opined
that a Cu feed pipe would look naff] ... however next time I'll channel
the (rear) wall and not have any supply pipe visible. with the service
valve inside the cistern. It's astonishing how 'tunnel vision'
overcomes one when the 'bog' is out-of-service for even a short time.


I'm rather surprised. Olives bind onto copper pipe through shrinkage and
a thin layer of chrome shouldn't have any effect. If there's any doubt I
would give the fitting another 1/2 turn to ensure the olive shrinks down
and binds onto the pipe.

Yep! {as I've stated , my experience is of only two} ... tried the 'normal
amount of torque'; turned water ON; both connections spurting water; tried
re-tightening the nuts, water spurting still; dismantled junctions,
sand-papered off chrome; reassembled - new olives (just to be safe),
tightened (normally) reapplied water - no drips. [I learnt from that ...].

BTW; I can't agree that distortion under pressure equates to 'shrinkage'.
--

Brian


  #19   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 4,410
Default Compression fittings on chrome pipe


"Andrew Mawson" wrote in message
...
....
IIUI there is absolutely no need to remove the chrome plating under
the olive, the olive will crush seal onto the chrome quite
satisfactorily


You need the olive to cut into the copper for a secure seal. Chrome is hard,
which makes it difficult to break through, and brittle, which means it will
crack and break into pieces, rather than deform, potentially making the seal
less secure.

Colin Bignell


  #20   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,158
Default Compression fittings on chrome pipe


"nightjar .uk.com" nightjar@insert my surname here wrote in
message news

"Andrew Mawson" wrote in

message
...
...
IIUI there is absolutely no need to remove the chrome plating

under
the olive, the olive will crush seal onto the chrome quite
satisfactorily


You need the olive to cut into the copper for a secure seal. Chrome

is hard,
which makes it difficult to break through, and brittle, which means

it will
crack and break into pieces, rather than deform, potentially making

the seal
less secure.

Colin Bignell



But so is stainless steel much harder than copper. I've installed
loads of stainless 15mm in high pressure hydraulic oil systems using
normal 15mm compression fittings in an agressive foundry environment,
and the only leak I've ever had was when a steel billet was dropped on
the pipe! Even then the joint was ok but the pipe fractured !!!

AWEM




  #21   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3,703
Default Compression fittings on chrome pipe

In article , Brian Sharrock
writes

BTW; I can't agree that distortion under pressure equates to 'shrinkage'.


Agreed, it's a very misused word, used extensively in retail to describe
staff theft (theft by staff :-).
--
fred
Plusnet - I hope you like vanilla
  #22   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 4,410
Default Compression fittings on chrome pipe


"Andrew Mawson" wrote in message
...
....
But so is stainless steel much harder than copper.


The important difference is that stainless is ductile, while chromium is
brittle.

Colin Bignell


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Brass Compression Fittings,Fittings for Pex-Al-Pex good price valvetom Home Repair 1 November 27th 06 06:20 PM
Compression fittings and Plastic pipe - a cautionary tale NoSpam UK diy 7 October 5th 06 11:09 AM
Chrome compression with plastic Davao UK diy 10 June 18th 06 09:35 AM
compression fittings on plastic pipe andyv UK diy 5 May 29th 06 11:51 PM
Joining 22mm compression fittings to brass pipe Ken Adam UK diy 11 May 15th 04 07:20 PM


All times are GMT +1. The time now is 05:32 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"