Hi,

Once an unvented central heating system is up to temperature, how often
would one expect the boiler to fire, and for how long?

Mine seems to go on and off in fairly quick cycles, although I haven't
actually sat down and measured them (it would involve sitting on the
toilet, as its inaudible from most of the house).

Thanks for any advice
- Ian

--
Ian Chard, Senior Unix and Network Admin | E:
Systems and Electronic Resources Service | T: 80587 / (01865) 280587
Oxford University Library Services | F: (01865) 242287
  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 8
Default Short firing -- how short is short?


"Ian Chard" wrote in message
...
Hi,

Once an unvented central heating system is up to temperature, how often
would one expect the boiler to fire, and for how long?


Depends on the outside temperature in relation to thermostat settings. My
geriatric system goes off and on about twice per minute at -10deg C outside
and thermostats set to maximum (20c) inside. Under less onerous conditions
it might be only once in ten minutes or even less.

rusty




  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 11,175
Default Short firing -- how short is short?

In article ,
Ian Chard writes:
Hi,

Once an unvented central heating system is up to temperature, how often
would one expect the boiler to fire, and for how long?


This really is a "how long is a piece of string" question.

Mine seems to go on and off in fairly quick cycles, although I haven't
actually sat down and measured them (it would involve sitting on the
toilet, as its inaudible from most of the house).


If it's a non-modulating boiler, then it is designed to switch
on and off in order to reduce the heat output to match what the
radiators can dissipate.

If it is doing this when the house isn't up to the thermostat
temperature, then you will improve things by turning up the
water temperature, as this will increase the power output from
the radiators, and they will do a better job of keeping up with
the boiler output. When the house is up to temperature, you
can then knock the boiler temperature down a bit for more
efficient operation.

You might get more useful advice if you gave the boiler model
and power output.

--
Andrew Gabriel
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
I Have a Short Somewhere ? [email protected] Home Repair 3 November 18th 06 08:55 PM
short JB UK diy 2 October 9th 06 10:13 AM
Adiabatic short-circuit compliance on very short short-circuits Will Dean UK diy 17 August 23rd 05 12:03 PM
Clamps too short Corey Woodworking 9 February 17th 05 01:01 AM
Short Film Bernie Bober Woodturning 2 July 24th 03 06:11 AM


All times are GMT +1. The time now is 09:30 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"