Can anyone give me a quick idea on the BTU requirements for a radiator for a
bathroom - approx 2metres square. insulated ceiling - 1920's walls - double
glazed window.

Thanks
--


--
John



  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 25,191
Default BTU for bathroom

John wrote:

Can anyone give me a quick idea on the BTU requirements for a radiator for a
bathroom - approx 2metres square. insulated ceiling - 1920's walls - double
glazed window.


Not without knowing how many walls are "outside" walls, and what rooms
adjoin it to the sides and above and below.

--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/
  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 408
Default BTU for bathroom


"John Rumm" wrote in message
...
John wrote:

Can anyone give me a quick idea on the BTU requirements for a radiator
for a bathroom - approx 2metres square. insulated ceiling - 1920's
walls - double glazed window.


Not without knowing how many walls are "outside" walls, and what rooms
adjoin it to the sides and above and below.

--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\=



================================================== ==============/



Two outside walls - two internal stud walls. Bedroom and landing.

Thanks


  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 7
Default BTU for bathroom

John wrote:
"John Rumm" wrote in message
...

John wrote:


Can anyone give me a quick idea on the BTU requirements for a radiator
for a bathroom - approx 2metres square. insulated ceiling - 1920's
walls - double glazed window.


Not without knowing how many walls are "outside" walls, and what rooms
adjoin it to the sides and above and below.

--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\=




================================================== ==============/



Two outside walls - two internal stud walls. Bedroom and landing.

Thanks


have a look on the B&Q website - they have a BTU calc on there.
  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 408
Default BTU for bathroom


"Mike Hibbert" wrote in message
...
John wrote:
"John Rumm" wrote in message
...

John wrote:


Can anyone give me a quick idea on the BTU requirements for a radiator
for a bathroom - approx 2metres square. insulated ceiling - 1920's
walls - double glazed window.

Not without knowing how many walls are "outside" walls, and what rooms
adjoin it to the sides and above and below.

--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\=




================================================== ==============/



Two outside walls - two internal stud walls. Bedroom and landing.

Thanks

have a look on the B&Q website - they have a BTU calc on there.



Done it - thanks




  #6   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1
Default BTU for bathroom


John Wrote:
Can anyone give me a quick idea on the BTU requirements for a radiator
for a
bathroom - approx 2metres square. insulated ceiling - 1920's walls -
double
glazed window.

Thanks
-- -


--
John -


Using a "mears" calculator, a 6'6" x 6'6" bathroom, 7'6" ceiling
hieght, 2 outside (solid 9")walls, on the first floor, design temp of
72 degrees, gives a BTU requirement of 3200.




--
Nick H
  #7   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 9,045
Default BTU for bathroom

John wrote:
Can anyone give me a quick idea on the BTU requirements for a radiator for a
bathroom - approx 2metres square. insulated ceiling - 1920's walls - double
glazed window.

Thanks


About 500W.
  #8   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 11,175
Default BTU for bathroom

In article ,
The Natural Philosopher writes:
John wrote:
Can anyone give me a quick idea on the BTU requirements for a radiator for a
bathroom - approx 2metres square. insulated ceiling - 1920's walls - double
glazed window.


About 500W.


I calculated 875W for a bathroom 1.2m x 2.4m, 9" brick walls
(two external), insulated ceiling, small double glazed window,
using the Myson calculator. In practice, the Myson calculator
seems to have over estimated throughout the whole house (it
was a beta version), although that has meant I can run the
boiler at only 45C once house has warmed up, making the
condensing boiler very efficient, so I'm not complaining.

--
Andrew Gabriel
  #11   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 25,191
Default BTU for bathroom

Andrew Gabriel wrote:

I calculated 875W for a bathroom 1.2m x 2.4m, 9" brick walls
(two external), insulated ceiling, small double glazed window,


That reminds me... I did a set of calcs for our place prior to doing the
loft conversion etc. The existing bathroom came out thus:

Surface Air
Area Tdelta u-val Loss Change Vol

Land wall 4.83 6 1.2 35 0.50 10
office wall 4.6 4 1.2 22
side wall 4.6 25 2.2 253
rear wall 2.83 25 2.2 156
window 2 25 2.9 145
floor 4.2 4 1.5 25
ceiling 4.2 4 1.9 32

Total 668 43 711

So 711W for a simlar sized room - two 10" solid exterior walls, two
internal stud walls, kitchen under, loft over.

--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On



All times are GMT +1. The time now is 09:13 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"