Default Shower plumbing advice please

Hi, bought a jacuzzi shower bath of ebay. Has an L-shaped shower panel
which has a thermostatic shower and extra body jets. I have three
questions about plumbing it in to a bathroom I'm building between two
bedrooms please.

1. It came with a large 3-bar shower pump but I would like to avoid
using this if possible because of wasted water and pump noise.
I have 2.5m from the top of the cold cistern to the shower head and
about 4m to the bottom of the hot tank- not plumbed in yet so can't
measure actual pressure - will this be enough (I'm not too
concerned if body jets, which can be turned off, don't work
properly)?

2. Also, there are two inlets to the shower thermostatic valve - hot
and cold. These go to the body jets and shower head. There is an
additional hot flexible pipe from the thermostatic valve. Does this go
to the bath mixer tap (it's the only place I can see to connect it
and it is not mentioned in the instructions)?

3. Would it be ok to run a hot supply directly to the bath mixer tap
(in case I need to use the pump for the shower).

Thank you

  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 25,191
Default Shower plumbing advice please

nafuk wrote:

1. It came with a large 3-bar shower pump but I would like to avoid
using this if possible because of wasted water and pump noise.
I have 2.5m from the top of the cold cistern to the shower head and
about 4m to the bottom of the hot tank- not plumbed in yet so can't
measure actual pressure - will this be enough (I'm not too
concerned if body jets, which can be turned off, don't work
properly)?


Distance to the hot cylinder is not relevent here, just the height
difference between the water level in the cold cistern and the shower head.

So you will get less than 0.25 bar pressure at the shower - which is on
the poor side of feeble.

I would count on using the pump if I were you.

2. Also, there are two inlets to the shower thermostatic valve - hot
and cold. These go to the body jets and shower head. There is an


That does not quite make sense. I would expect hot and cold inlets, and
then outlets to shower head and body jets.

additional hot flexible pipe from the thermostatic valve. Does this go
to the bath mixer tap (it's the only place I can see to connect it
and it is not mentioned in the instructions)?


This could be a water feed to the jacuzzi section - some systems
(especially those that pump air through the water) allow the injection
of warm water to maintain the temperature of the bath, and also to
eliminate any "chill" sensation from the air. Can you not find any more
details on the makers web site?

3. Would it be ok to run a hot supply directly to the bath mixer tap
(in case I need to use the pump for the shower).


You could, but check the taps are suitable for low presssure operation.
I would be more inclinded to feed the bath taps from the pumped supply
as well.

--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Are You Looking For Aquasana Shower Filters With Discount Price nitin Home Ownership 0 April 21st 06 10:48 AM
How to replace shower plumbing. [email protected] Home Repair 11 April 11th 06 11:56 AM
Air in plumbing system causing leaks in shower thermostatic valve?? peter UK diy 0 January 10th 06 04:23 PM
Electric shower advice please Broadback UK diy 9 August 10th 04 08:33 AM
Replacing electric shower - advice? Marshal Anderson UK diy 2 September 15th 03 02:18 PM


All times are GMT +1. The time now is 02:11 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"