UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to uk.d-i-y
TheScullster
 
Posts: n/a
Default Notch, Hole and Chase Sizes

Hi all

Reviewing Part P last night there is a reference to Part A for notch and
hole sizes in joists and chases in walls.
Looked through Part A and can't find any sign of this.
Am I missing something here?
I have found other reference on diydoctor but not "official" data.

Phil


  #2   Report Post  
Posted to uk.d-i-y
John McLean
 
Posts: n/a
Default Notch, Hole and Chase Sizes


"TheScullster" wrote in message
...
Hi all

Reviewing Part P last night there is a reference to Part A for notch and
hole sizes in joists and chases in walls.
Looked through Part A and can't find any sign of this.
Am I missing something here?
I have found other reference on diydoctor but not "official" data.

Phil


This is approved Document A-Structu of the Building Regulations.

..a. notches should be within the following limits:

· no deeper than 0.125 the depth of the joist

· not closer to the support than 0.07 of the span.

· not further away from the support than 0.25 times the span.

b. holes should be within the following limits:

· no greater diameter than 0.25 times the depth of the joist.

· made at the neutral axis (where the joist is under least tension,
normally at the centreline of the joist depth).

· not be less than 3 diameters (centre to centre) apart.

· located between 0.25 and 0.4 times the span from the support.

Note that notches and holes are not permitted in roof rafters, to prevent
damage to the roof structure.

Jaymack


  #3   Report Post  
Posted to uk.d-i-y
TheScullster
 
Posts: n/a
Default Notch, Hole and Chase Sizes


"John McLean" wrote

This is approved Document A-Structu of the Building Regulations.

.a. notches should be within the following limits:

· no deeper than 0.125 the depth of the joist

............snip


Thanks John

But I looked through the on-line version of Part A - 2004 and couldn't find
that stuff anywhere!
Which year/edition did you get these from and page number?
Are my glasses in need of replacement or something?

TIA

Phil


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Question on chimney chase top repair Ted Swirsky Home Repair 1 November 3rd 05 01:37 AM


All times are GMT +1. The time now is 10:05 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"