UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions.

 
 
LinkBack Thread Tools Search this Thread Display Modes
Prev Previous Post   Next Post Next
  #1   Report Post  
Posted to uk.d-i-y
ian
 
Posts: n/a
Default Comsumer unit RCD trips on non-RCD protected circuit activity

Hi,

I've got an 8/9 yr old bungalow and a split consumer unit where (only) the
ring main and garage circuit breakers are protected by a 30ma/100A RCD trip
switch.

Today, this trip started going at almost any opportunity: unplugging and
resetting didn't help much as any random device may or may not cause the
switch to trip, and sometimes it took a minute before it went. Once it
tripped when I dropped a 4 way extension block that had no devices connected
to it.

I borrowed a PAT tester to check for leakage and plugged it into the cooker
socket as that is not protected by the RCD, but there wasn't much (only found
0.1mA from one device and after checking all bar a couple of devices the rest
were solidly 0.0mA). When I plugged a hair dryer into the PAT unit and ran it
up on full power the RCD tripped again. This doesn't fill me with confidence
as the consumer unit has a split live rail and the RCD is 'downstream' from
the cooker circuit breaker - I don't think it was something else switching on
on the protected ring as the same set of appliances didn't trip it out for
five minutes afterwards.

The general consensus I've got offline so far is that my wiring is stuffed.
I'm having the loft converted at the moment but the new rings have not yet been
connected to the consumer unit, and there has been no-one doing any work for
over three weeks (that's another rant, but serves me right for not DIY, I
suppose I've asked for the electrician doing the work to return, but not
heard back from him so far, so I'm looking for advice on tracking things down
a bit.

I will test the remaining devices for leakage (UPSes, which kicked in fine
when the RCD tripped, so I think they're ok) but after that the best advice
I've had is to remove every device from the ring main and turn it off, then
remove all the socket fronts and check the tightness of the wiring, followed
by plugging things back one at a time. The wiring check seems fine, but as
it's a random selection of devices and never just one that causes the problem,
I don't know how putting them back individually might help.

Does anyone have experience of tracking down stuff like this ? Is it worth
turning off the consumer unit and doing the N1-N2, L1-L2 tests mentioned in
the FAQ ?

Thanks in advance,
--
Ian Spray
 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Help! RCD trips on Volex consumer unit no matter what I do! [email protected] UK diy 18 April 3rd 05 05:17 PM
circuit breaker trips jozep7075 Home Ownership 4 January 14th 05 10:53 PM
Typical domestic electrical circuits John Aston UK diy 21 January 21st 04 03:10 PM
RCD trips while working on dead circuit Bob Mannix UK diy 4 September 9th 03 09:31 AM
Whirlpool Washer trips circuit breaker in spin cylce Mike Home Repair 6 August 24th 03 06:35 AM


All times are GMT +1. The time now is 12:40 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"