Hi,
Is expanding foam safe to use in contact with PVC sheathed cables?

Thanks

Jim


  #2   Report Post  
Posted to uk.d-i-y
sPoNiX
 
Posts: n/a
Default Cables and expanding (ureathane) foam

On Tue, 24 Jan 2006 13:17:34 -0000, "Jim Ingram"
wrote:

Hi,
Is expanding foam safe to use in contact with PVC sheathed cables?


I'd err on the side of caution.

PVC cable in contact with polystyrene tends to melt the polystyrene. I
imagine it would do the same with expanding foam.

Perhaps worth calling/emailing the manufaturer of the foam and asking
them?

sponix
  #3   Report Post  
Posted to uk.d-i-y
Rick
 
Posts: n/a
Default Cables and expanding (ureathane) foam

On Tue, 24 Jan 2006 13:17:34 -0000, "Jim Ingram"
wrote:

Hi,
Is expanding foam safe to use in contact with PVC sheathed cables?

Thanks

Jim


You may have the issue that it will insulate the cables, and reduce
their current carrying capacity. The expanding foam has quite a good U
value.

Rick

  #4   Report Post  
Posted to uk.d-i-y
Andy Dingley
 
Posts: n/a
Default Cables and expanding (ureathane) foam

On Tue, 24 Jan 2006 13:17:34 -0000, "Jim Ingram"
wrote:

Is expanding foam safe to use in contact with PVC sheathed cables?


Compared to the problem with PVC plasticisers damaging polystyrene foam,
yes.
  #5   Report Post  
Posted to uk.d-i-y
John Rumm
 
Posts: n/a
Default Cables and expanding (ureathane) foam

Jim Ingram wrote:

Is expanding foam safe to use in contact with PVC sheathed cables?


Yup... at least there is no leaching plasticizer pproblem. However you
may need to apply derating to the cables current capacity if any length
of it is buried in the insulation.


--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Bathroom bonding and cables through floors Jason Pearce UK diy 4 October 12th 04 06:44 PM


All times are GMT +1. The time now is 01:49 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"