I have a stud wall in my house that is 85mm uprights with 20mm lathe
and plaster each side.

I have access to the inside of this wall (at the top and bottom) at one
place along the wall, and would like to run cables down it for a ring
main. The regs say that cables must be at least 50mm deep if they are
unprotected. There is an area 25mm wide that is 50mm from each side of
the wall.

So, should I run my cables in this wall?

Would I be better off putting them close to one of the sides of the
wall and adding a socket in the same area (to turn it into a permidded
zone)?

Comments please...

  #2   Report Post  
Posted to uk.d-i-y
Sadly
 
Posts: n/a
Default Running ring main inside stud-wall

No comments?

  #3   Report Post  
Posted to uk.d-i-y
Andy Wade
 
Posts: n/a
Default Running ring main inside stud-wall

Sadly wrote:

I have a stud wall in my house that is 85mm uprights with 20mm lathe
and plaster each side.


It's lath and plaster. A lathe is a machine tool...

I have access to the inside of this wall (at the top and bottom) at one
place along the wall, and would like to run cables down it for a ring
main. The regs say that cables must be at least 50mm deep if they are
unprotected. There is an area 25mm wide that is 50mm from each side of
the wall.

So, should I run my cables in this wall?


The problem here is that with access at only those three points you
couldn't fix the cable well enough to constrain it to that middle inch.
If you're prepared to knock in two more holes and clip at five points
it might just be OK.

Would I be better off putting them close to one of the sides of the
wall and adding a socket in the same area (to turn it into a permidded
zone)?


That's certainly an option, and then it wouldn't matter where the cable
went within the thickness of the wall (assuming the switch or socket
location can be determined from both sides of the wall) - but you'd
still need to constrain it to a accurate horizontal or vertical run to
the electrical fitting.

Comments please...


Does that help?
--
Andy
  #4   Report Post  
Posted to uk.d-i-y
Mr Fuxit
 
Posts: n/a
Default Running ring main inside stud-wall

Just drop the cables down the cavity; who the hell is going to see them?

  #5   Report Post  
Posted to uk.d-i-y
chris French
 
Posts: n/a
Default Running ring main inside stud-wall

In message .com, Mr
Fuxit writes
Just drop the cables down the cavity; who the hell is going to see them?


Not the person in the future who drills into it/puts a screw through it
etc.....

Which is the point really.
--
Chris French



  #6   Report Post  
Posted to uk.d-i-y
Mr Fuxit
 
Posts: n/a
Default Running ring main inside stud-wall

I've never, ever, seen cables clipped or otherwise fixed inside a
studwork cavity. Also, only a complete idiot drills above a socket or
switch. Finally, there's more danger of damaging a fixed cable than a
cable that can be pushed aside by a drill bit.

  #7   Report Post  
Posted to uk.d-i-y
 
Posts: n/a
Default Running ring main inside stud-wall


Mr Fuxit wrote:

Finally, there's more danger of damaging a fixed cable than a cable that can be pushed
aside by a drill bit.


Not likely though is it.

I agree that a masonry bit isn't that sharp, but a wood drill would rip
up the sheath quite well.

Still, this is lath and plaster, Who knows what someone'd drill into it
with.

P.

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
stud partition 'butress' first floor wig UK diy 4 April 28th 05 01:41 AM
Ring Main Wiring Mark Carver UK diy 31 March 7th 05 06:31 PM
HELP: vertical foundation crack in new construction Zhixin Tang Home Ownership 25 October 26th 03 01:53 PM
Damp inside loft wall Orb UK diy 2 August 22nd 03 11:18 AM
Building an internal wall - brick or stud? steve UK diy 6 July 24th 03 09:40 AM


All times are GMT +1. The time now is 01:57 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"