UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions.

 
 
LinkBack Thread Tools Search this Thread Display Modes
Prev Previous Post   Next Post Next
  #1   Report Post  
Posted to uk.d-i-y
John Rumm
 
Posts: n/a
Default Problem with gas fire power flue

A mate asked me to work out why his powered flue gas fire was no longer
working. The setup is an inset style coal effect gas fire with an input
of about 6.2kW. It has an add on powered flue fitted since it sits in a
fake chimney breast that does not have a real chimney above.

The lighting procedure was to turn on the flue (via a switched FCU
beside the fireplace), then go through the pilot lighting sequence using
the control on the fire. First obvious problem was the flue was not
powering up. I am not sure how the ignition inhibit between flue and
fire works, although I assume that there is one, since it was not
possible to even light the pilot.

I took the external box apart and found a blown internal 20mm glass
cartridge fuse. Replaced it with the spare conveniently cable tied to
the inside of the box! reassembled, powered it up and it sprang into
life again. Was just about to try lighting the fire when the flue
stopped again - presumably having blown the new fuse. It was late, dark
and cold, so we suspended deeper investigations until later. (Alas, I
was not able to locate a make or model number on the flue)

So, any suggestions for typical failure modes and diagnostic procedures
for these things? The motor/fan sounded like it was spinning freely when
it ran briefly. My initial plan was to measure the current consumption
as a starting point to see how far from the fuse value it actually is.

One issue I did notice however was that the mains voltage at the time
was very low (about 205V - which apparently is common in the evening in
his neck of the woods). I presume these units have induction motors to
drive the fan, but would they typically fuse them with so little margin
that the current rise caused by a low supply voltage would take out the
fuse?



--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/
 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Metal Working Machinery New and Used in Australia and for Export [email protected] Metalworking 0 February 23rd 05 02:54 AM
Hitachi power problem persists [email protected] Electronics Repair 2 January 27th 05 11:25 AM
pc power supply failure? Al Electronics Repair 9 January 23rd 05 11:15 PM
Gas fire flue extract... Magog UK diy 0 February 28th 04 01:46 PM
Advice on living flame gas fire Stuart UK diy 11 December 2nd 03 11:47 AM


All times are GMT +1. The time now is 11:12 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"